Hilti GX 100 Operating Instructions Manual page 25

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 16
1.Remove gas can
If this is possible go to step 2
from tool
If this is not possible go to step
1.1
If you are still not able to remove gas can send tool to Hilti Repair Center.
Important: Gas can has to be declared as Hazard Material for shipment!!
3. Remove
2. Remove sleeve
remaining nails.
assy X-100TN by
Disassemble
first pressing spring
magazine from
clip and turning
tool.
sleeve assy.
Clear all debris from the tool prior to reassembling.
Sleeve assy X-100TN is not
returning to starting position
Piston jams
Small plastic particle or nail debris can get stuck
in fastener guide which causes the piston to not
return to the starting position.
Printed: 07.07.2013 | Doc-Nr: PUB / 5069869 / 000 / 00
1.1 Press valve head toward the outside in the
direction of the arrow until valve head is
disconnected from gas can. Remove valve
head and gas can.
4. Remove
5. If nail can’t
jammed nails
be removed
with pliers or
with pliers, tap
edge cutter.
nail back. .
6. Free nail with nail
punch X-100NP and
hammer.