Advertisement

Quick Links

HumaRock
| User Manual
Cat No. 145701

Advertisement

Table of Contents
loading

Summary of Contents for Human HumaRock

  • Page 1 HumaRock | User Manual Cat No. 145701...
  • Page 3 No part of this documentation may be reproduced in any form, nor processed, copied or distribut- ed by means of electronic systems, without prior permission of Human GmbH in writing. Since all precautionary measures were taken into account in producing these operating instructions, the manufacturer accepts no responsibility for any errors or omissions.
  • Page 5: Table Of Contents

    CONTENTS TABLE OF CONTENTS 1 SAFETY INSTRUCTIONS 1.1 INTRODUCTION 1.2 USER WARRANTY 1.3 INTENDED USE OF THE INSTRUMENT 1.4 GENERAL SAFETY WARNINGS 1.5 DISPOSAL MANAGEMENT CONCEPT 1.6 BIOHAZARD WARNING 1.7 INSTRUMENT DISINFECTION 1.8 SYMBOLS 2 DESCRIPTION 2.1 UNPACKING 2.1.1 Receiving Inspection 2.1.2 Listing of Items 2.2 CONTROL 2.3 ABBREVIATIONS...
  • Page 6 CONTENTS...
  • Page 7: Safety Instructions

    HUMAN, not regularly maintained, used with equipment not approved by HUMAN or used for purposes for which it was not designed.
  • Page 8: Intended Use Of The Instrument

    For cleaning use only materials specified in this manual, otherwise parts may become damaged. It is recommended always to wear protective apparel and eye protection while using this instrument. Respective warning symbols, if appea- ring in this manual, should be carefully considered. HumaRock | User manual...
  • Page 9: Disposal Management Concept

    Safety InStructIonS 1.5 Disposal Management Concept The currently valid local regulations governing disposal must be observed. It is in the responsibility of the user to arrange proper disposal of the individual components. All parts which may comprise potentially infectious materials have to be disinfected by suitable validated procedures (autoclaving, chemical treatment) prior to disposal.
  • Page 10: Instrument Disinfection

    1.8 Symbols Warning! Read the operating instructions carefully before use. Ensure that only trained staff works with the instrument. Protective ground contact! Ensure the socket must be grounded (protective ground contact) before use. HumaRock | User manual...
  • Page 11: Description

    Chapter 1. Do not use the accessories recommended by the manufacturer, or failure to use the instructions, may be caused unsafe situation. The HumaRock rocking shaker is manufactured in accordance with the follow- ing standards: EN 61010-1, EN 61326-1 2.1 Unpacking...
  • Page 12: Control

    Speed control knob Set target speed. Power switch Switch ON/OFF instrument. Power interface Connect the power cable Power light Green LED display light 2.3 Abbreviations revolutions per minute watt volt Hertz kilogram milimeter centimeter mililiter decibel HumaRock | User manual...
  • Page 13: Routine Utilization

    routIne utIlIzatIon 3 ROUTINE UTILIZATION 3.1 Operation Place the instrument in safe and stable surface, ensure the required opera- ting voltage and power supply voltage matched. Connect the power cable. Install the platform. Switch ON the instrument. Rotate the speed control knob clockwise to set target speed, and the shaking function will be switched on.
  • Page 14 HumaRock | User manual...
  • Page 15: Maintenance

    MaIntenance 4 MAINTENANCE Proper maintenance can keep instrument working properly and lengthen its lifetime. Do not spray cleanser into the instrument when cleaning. Do not remove the power line when cleaning. Only use recommended clean- sers: Dyes Isopropyl alcohol Construction Materials Water containing tenside / Isopropyl alcohol Cosmetics Water containing tenside / Isopropyl alcohol...
  • Page 16 HumaRock | User manual...
  • Page 17: Troubleshooting

    troubleShootIng 5 TROUBLESHOOTING When switched ON, the instrument does not work Check whether the power cable is connected Motor speed cannot reach set value Check whether it is overloaded...
  • Page 18 HumaRock | User manual...
  • Page 19: Appendix

    Protection class acc. DIN EN60529 IP21 Maximum altitude 4000m Noise level <50 dB 6.2 Accessories and Consumables Cat. No. Descriptions HumaRock, Analog Rocking Shaker, See-saw wave, angle 7, 14570 US/UK/EU plug, 100V-240V, 50Hz/60Hz Accessories Cat. No. Descriptions 14570/10 Universal attachment with 3 bars 14570/20...
  • Page 20 Fixing clip for flask volume 50 ml 14570/17 Fixing clip for flask volume 100 ml 14570/18 Fixing clip for flask volume 200/250 ml 14570/19 Fixing clip for flask volume 500 ml Bar for 14570/10 Universal attachment, 14570/14 black HumaRock | User manual...
  • Page 22 HumaRock | User manual...
  • Page 24 HUMAN Gesellschaft für Biochemica und Diagnostica mbH Max-Planck-Ring 21 • 65205 Wiesbaden • Germany Tel.: +49 6122/9988 0 • Fax: +49 6122/9988 100 eMail: human@human.de • www.human.de...

Table of Contents