Summary of Contents for Human HuMax 14K

  • Page 1 HuMax 14K | User Manual Cat No. 17160/1...
  • Page 3 No part of this documentation may be reproduced in any form, nor processed, copied or distributed by means of electronic systems, without prior permission of HUMAN in writing. Since all precautionary measures were taken into account in producing these operating instructions, the manufacturer accepts no responsibility for any errors or omissions.
  • Page 5: Table Of Contents

    CONTENTS TABLE OF CONTENTS 1 SAFETY INSTRUCTIONS 1.1 INTRODUCTION 1.2 USER WARRANTY 1.3 INTENDED USE OF THE INSTRUMENT 1.4 GENERAL SAFETY WARNINGS 1.5 DISPOSAL MANAGEMENT CONCEPT 1.6 INSTRUMENT DISINFECTION 1.7 BIOHAZARD WARNING 2 MAIN PURPOSE OF THE UNIT AND DESCRIPTION 3 TECHNICAL SPECIFICATIONS 3.1 TECHNICAL SPECIFICATIONS TABLE 3.2 OPERATING PRINCIPLES...
  • Page 6 6.1 PERIODICAL MAINTENANCE 6.2 DISINFECTION / STERILISATION 6.3 CORROSION INFORMATION 6.3.1 Chemical Corrosion 6.3.2 Stress Corrosion 6.4 CLEANING 6.5 ELECTRICITY 7 TROUBLESHOOTING 8 ELECTRICAL CIRCUIT DIAGRAMS 8.1 ELECTRICAL CIRCUIT DIAGRAM OF HUMAX 14K 8.2 ELECTRICAL CIRCUIT DIAGRAM OF HUMAX 14K R...
  • Page 7 CONTENTS...
  • Page 9: Safety Instructions

    HUMAN, not regularly maintained, used with equipment not approved by HUMAN or used for purposes for which it was not designed.
  • Page 10: Intended Use Of The Instrument

    1.4 General safety warnings Use only chemical reagents and accessories specified and supplied by HUMAN and/or mentioned in this manual. Place the product so that it has proper ventilation. The instrument should be installed on a stationary flat working surface, free from vibrations.
  • Page 11: Disposal Management Concept

    1.6 Instrument disinfection Analytical instruments for in vitro diagnostic involve the handling of human samples and controls which should be considered at least potentially infec- tious. Therefore every part and accessory of the respective instrument which may have come into contact with such samples must equally be considered as potentially infectious.
  • Page 12: Biohazard Warning

    1.7 Biohazard warning Analytical instruments for in vitro diagnostic application involve the handling of human samples and controls which should be considered at least potentially in- fectious. Therefore every part and accessory of the respective instrument which may have come into contact with such samples must equally be considered as potentially infectious.
  • Page 13: Main Purpose Of The Unit And Description

    Different types of rotors, swing-out and angle rotors, can be fitted to the centrifuges. The microprocessor control system also displays the RCF value during the run. The ventilation system of the HuMax 14K limits temperature in the bowl at max. +12°C. The centrifuges are manufactured according to the following standards:...
  • Page 14 Gerätename | User manual...
  • Page 15: Technical Specifications

    SPecIfIcatIonS 3 TECHNICAL SPECIFICATIONS 3.1 Technical Specifications Table HuMax 14K TABLE 1 Max Speed 17161 rotor: 4100 rpm, 17163 rotor: 14000 rpm Max. RCF* 17161 rotor: 3045 x g, 17163 rotor: 18407 x g Max. Capacity 17161 rotor: 4x 200 ml, 17163 rotor: 24 x 1.5/2 ml...
  • Page 16: Imbalance Detection System

    The “Lid Open” indicator turns on to warn the user if the lid is not closed properly. 3.2.2 Imbalance Detection System The imbalance detection system of the HuMax 14K centrifuges operates electronically when an unacceptable imbalance occurs. In this case the brake is applied immediately.
  • Page 17: Rotor Selection Table

    tecHnIcaL SPecIfIcatIonS 3.3 Rotor Selection Table Rotor Description Capacity Max. Tube Rad mm Max. Speed Max RCF xg TABLE 2 Dim. mm 17161 Swing-Out Rotor 4x 200 ml Ø 57 4100 3045 17161/1 Set of 4 buckets 200 ml Ø 57 4100 3045 17161/3...
  • Page 18 FIGURE 3 1 Lid 2 Lock Pin 3 Gas Spring 4 Lid Gasket 5 Rotor 6 Manual LID Opening Hole 7 Control Panel 8 Bowl 9 Observation Window 10 On/Off Switch 11 Electrical Socket And Fuses 12 Air Ventilation Gerätename | User manual...
  • Page 19: Installation Procedure

    The centrifuge should be lifted from underneath and never be turned over. 4.2 Contents Of Package The package includes: 1 ea. HuMax 14K Centrifuge 1 ea. User manual 1 ea. Manual lid opening tool 1 ea. Electrical cable 1 ea.
  • Page 20: Positioning

    4.5 Positioning Make sure that no damage has occurred during transport. Make sure that the positioning is suitable for users. Lift the centrifuge underneath and carry it to its place. The bench-top must be rigid enough to support the weight and vibrations. Leave 30 cm free space on all sides of the centrifuge.
  • Page 21: Rotor Installation

    InStaLLatIon ProceDure 4.7.1 Rotor Installation Put some light oil on the drive head to prevent sticking. Be careful that the rotor fits on the drive shaft. Screw the shaft nut with socket wrench to the clockwise direction. Make sure that the shaft nut is screwed down tightly, but do not apply excessive torque.
  • Page 22 Imbalance of the rotor may cause major damage to the rotor and centrifuge. Never attempt to introduce liquids into the tube inserts. Balance the rotor with glass tubes if you use glass tubes for centrif- ugation. Balance the rotor with plastic tubes if you use plastic tubes for centrifugation.
  • Page 23: Control Panel And Indicators

    PaneL anD InDIcatorS 5 CONTROL PANEL AND INDICATORS 5.1 Control Panel, Display Please see below the front panel of the HuMax 14K R. FIGURE 5 Control Display Panel TABLE 3 KEY / INDICATOR FUNCTION (1) Status display Display of speed (500-14.000 rpm) or display of RCF (0-18.405 x g) during the run, rotor type during program-...
  • Page 24 (8) Acceleration It turns on while the acceleration rate is being pro- Indicator Led grammed and while the rotor is accelerating. (9) Braking Indicator This indicator turns on if the lid remains open or is not properly closed. (10) PULSE Button PULSE mode on if pushing button by during READY situa- tion.
  • Page 25: Preparing To Run

    controL PaneL anD InDIcatorS 5.2 Preparing to Run Switch on the centrifuge Open the lid Fit the rotor and balance the sample load Close the lid 5.3 Making a New Program Determine the rotor type, the speed and time, the acceleration and braking rates.
  • Page 26: Selecting The Memorized Program

    FIGURE 6 Angle Rotor (left), Swing-out Rotor (right) The correct rotor type should be selected in order to see the correct RCF values during the run. 5.3.1 Selecting the memorized program Select the requested program number at stand-by position by turning Encoder but- ton (6) value increase and decrease.
  • Page 27: Pulse Mode

    At the end of the cooling operation with the HuMax 14K centrifuges, dry with a non-wool soft cloth or paper towel at the centrifuge cell. (When the end of cooling operation with HuMax 14K, has a puddle at the centrifuge cell. So dry to water with paper towel and soft cloth.)
  • Page 28: Safety Interlock System

    5.5 SAFETY INTERLOCK SYSTEM The safety interlock system prevents opening of the lid when the rotor is spin- ning. The centrifuge does not operate until the lid is closed and the lid remains locked until the rotor stops spinning. The “Lid Open” indicator turns on to warn the user if the lid is not closed properly.
  • Page 29: Cleaning & Periodical Maintenance

    cLeanInG & PerIoDIcaL MaIntenance 6 CLEANING & PERIODICAL MAINTENANCE 6.1 Periodical Maintenance Disconnect the power cable and after the maintenance check the presence of the mains grounding line. Rotors should be washed after every use, especially if a spillage has occurred, in warm water containing a few drops of liquid soap.
  • Page 30: Corrosion Information

    6.3 Corrosion Information The HuMax rotors which are made of aluminum are designed to spin at prop- er RCF’s for many years. When used properly, their resistance to corrosion and their life span increases and the imbalance problems decrease. All accessories should be thoroughly checked regularly as almost all laboratory environments can easily lead to corrosion.
  • Page 31: Cleaning

    cLeanInG & PerIoDIcaL MaIntenance Every centrifugation causes the aluminium rotor to be attacked by the chemical more and more and eventually micro-cracks decrease the resistance of the ro- tor against the centrifugation force. Fortunately, no crash occurs just after the first micro-cracks have occurred as the rotors are manufactured according to the high safety limits.
  • Page 32 Gerätename | User manual...
  • Page 33: Troubleshooting

    trouBLeSHootInG 7 TROUBLESHOOTING If the centrifuge fails to operate, check that, The on/off switch is on, The fuses are sound, The plug is not defective, The centrifuge is well connected to the supply, The electricity installation is not defective, Power is supplied. In case of below written failures, related error codes are shown Err 1 Imbalance error.
  • Page 34 Gerätename | User manual...
  • Page 35: Electrical Circuit Diagrams

    DIaGraMS 8 ELECTRICAL CIRCUIT DIAGRAMS 8.1 Electrical Circuit Diagram of HuMax 14K FIGURE 9...
  • Page 36: Electrical Circuit Diagram Of Humax 14K R

    8.2 Electrical Circuit Diagram of HuMax 14K R FIGURE 10 Gerätename | User manual...
  • Page 37 MaIn PurPoSe of tHe unIt anD DeScrIPtIon...
  • Page 38 Gerätename | User manual...
  • Page 39 MaIn PurPoSe of tHe unIt anD DeScrIPtIon...
  • Page 40 Gerätename | User manual...
  • Page 42 HUMAN Gesellschaft für Biochemica und Diagnostica mbH Max-Planck-Ring 21 • 65205 Wiesbaden • Germany Tel.: +49 6122/9988 0 • Fax: +49 6122/9988 100 eMail: human@human.de • www.human.de...