31 |
DT 4.10, DT 4.16, DT 4.25, DT 4.40, DX 4.10, DX 4.16, DX 4.25, DX 4.40
Variant
Blowing air flow min.
Blowing air volume max.
Print
Weight
Sound level min.
Sound level max.
Permissible ambient
temperature
Exhaust air temperature max.
Maximum installation height
Maximum humidity of the
intake air
Table 9.2: Operating parameters
Variant
Blowing air flow min.
Blowing air volume max.
Print
Weight
Sound level min.
Sound level max.
Permissible ambient
temperature
Exhaust air temperature max.
Maximum installation height
Maximum humidity of the
intake air
Table 9.2: Operating parameters
9.3
TECHNICAL DATA
Technical data sheets for the pumps can be found on our homepage under the following link:
www.becker-international.com/download
DT 4.40 K
DT 4.40/0-80
40 m³/h (50 Hz)
40 m³/h (50 Hz)
48 m³/h (60 Hz)
48 m³/h (60 Hz)
1000 mbar (rel)
500 mbar (rel)
38 - 41 kg
38 - 41 kg
67 dB(A) (50 Hz)
67 dB(A) (50 Hz)
72 dB(A) (60 Hz)
72 dB(A) (60 Hz)
5 - 45 °C
126 °C
800 m ü.NN.
800 m ü.NN.
90 %
DX 4.25 K
DX 4.25/0-80
25 m³/h (50 Hz)
25 m³/h (50 Hz)
30 m³/h (60 Hz)
30 m³/h (60 Hz)
1000 mbar (rel)
600 mbar (rel)
26 - 29 kg
26 - 29 kg
62 dB(A) (50 Hz)
62 dB(A) (50 Hz)
67 dB(A) (60 Hz)
67 dB(A) (60 Hz)
5 - 45 °C
118 °C
800 m ü.NN.
800 m ü.NN.
90 %
DX 4.10
10 m³/h (50 Hz)
12 m³/h (60 Hz)
1000 mbar (rel)
16 kg
60 dB(A) (50 Hz)
62 dB(A) (60 Hz)
5 - 45 °C
5 - 45 °C
126 °C
87 °C
800 m ü.NN.
90 %
90 %
DX 4.40 K
40 m³/h (50 Hz)
48 m³/h (60 Hz)
1000 mbar (rel)
38 - 41 kg
67 dB(A) (50 Hz)
72 dB(A) (60 Hz)
5 - 45 °C
5 - 45 °C
118 °C
126 °C
800 m ü.NN.
90 %
90 %
DX 4.16
16 m³/h (50 Hz)
19 m³/h (60 Hz)
1000 mbar (rel)
23,5 kg
61 dB(A) (50 Hz)
64 dB(A) (60 Hz)
5 - 45 °C
93 °C
800 m ü.NN.
90 %
DX 4.40/0-80
40 m³/h (50 Hz)
48 m³/h (60 Hz)
500 mbar (rel)
26 - 29 kg
62 dB(A) (50 Hz)
67 dB(A) (60 Hz)
5 - 45 °C
118 °C
800 m ü.NN.
90 %