30 |
DT 4.10, DT 4.16, DT 4.25, DT 4.40, DX 4.10, DX 4.16, DX 4.25, DX 4.40
9
PRODUCT DATA SHEET
9.1
PRODUCT OVERVIEW
Example: DT 4.16
9.2
OPERATING PARAMETERS
Variant
Blowing air flow min.
Blowing air volume max.
Print
Weight
Sound level min.
Sound level max.
Permissible ambient
temperature
Exhaust air temperature max.
Maximum installation height
Maximum humidity of the
intake air
Table 9.2: Operating parameters
DT 4.10
10 m³/h (50 Hz)
16 m³/h (50 Hz)
12 m³/h (60 Hz)
19 m³/h (60 Hz)
1000 mbar (rel)
1000 mbar (rel)
16 kg
60 dB(A) (50 Hz)
61 dB(A) (50 Hz)
62 dB(A) (60 Hz)
64 dB(A) (60 Hz)
5 - 45 °C
87 °C
800 m ü.NN.
800 m ü.NN.
90 %
DT 4.16
DT 4.25 K
25 m³/h (50 Hz)
30 m³/h (60 Hz)
1000 mbar (rel)
23,5 kg
26 - 29 kg
62 dB(A) (50 Hz)
67 dB(A) (60 Hz)
5 - 45 °C
5 - 45 °C
93 °C
118 °C
800 m ü.NN.
90 %
90 %
DT 4.25/0-80
25 m³/h (50 Hz)
30 m³/h (60 Hz)
600 mbar (rel)
26 - 29 kg
62 dB(A) (50 Hz)
67 dB(A) (60 Hz)
5 - 45 °C
118 °C
800 m ü.NN.
90 %