JLG 0300208529 Operation And Safety Manual page 108

Table of Contents

Advertisement

SECTION 7 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE
3.
Hydraulic Tank
Lube Point(s) - Fill Cap
Capacity - 4 Gal. (15.1 L)
Lube - HO
Interval - Check Level daily; Change every 2 years or 1200
hours of operation.
Comments - On new machines, those recently overhauled, or
after changing hydraulic oil, operate all systems a minimum of
two complete cycles and recheck oil level in reservoir.
E450
M450
3121713
7-11

Advertisement

Table of Contents
loading

This manual is also suitable for:

E450ajM450ajE450a0300272287B300001429B300005763

Table of Contents