13. TROUBLESHOOTING GUIDE

Possible cause
The
space
around
inadequate for ventilation
The refrigeration system is working in
DEFROST mode
The condenser fins are clogged with
airborne particles
Fan motor is not running
Refrigerant is leaking
The solenoid valve is faulty
The thermostat is faulty
Electrical components of the compressor
are not functioning
not
Some
electrical
complete
The compressor is malfunctioning
The fan motor blades are hitting internal
components
The
main
cover
assembled
Some
electrical
complete
The main power switch is broken
The thermostat is faulty
The gear motor is malfunctioning
One of the bowl seal is not in place
is
The
dispensing
incompletely or incorrectly replaced in its
position
The free movement of the valve is
impeded
Dispensing valve o-rings are damaged
The bell shaped seal between the front of
the cylinder and the auger hub has not
been reinstalled properly
The bell shaped shaft seal or the spindle
bushing seal is damaged or worn
The
main
cover
assembled
Some
electrical
complete
The gear motor is malfunctioning
The bell shaped shaft seal has been
replaced
without
damaged
The auger has been incompletely or
incorrectly reassembled
the
machine
is
connections
are
not
is
not
correctly
connections
are
not
valve
has
been
is
not
correctly
connections
are
not
lubrication
or
is
Revision: 0
Solution
Allow at least 20cm between the
machine and anything next to it;
keep it away from heat sources
Return to FREEZE mode
Clean the condenser fins
Check the fan motor's electrical
connections and, if disconnected,
reconnect. If still not operating,
replace the motor
Locate the leak, eliminate it and
recharge the system
Replace the solenoid valve
Replace the thermostat
Replace
the
malfunctioning
components
Check the contacts and correct
those incomplete
Replace the compressor
Check and correct
Assemble
the
main
correctly
Check the contacts and correct
those incomplete
Replace the switch
Replace the thermostat
Replace the gear motor
Replace or reposition the seal
Reassemble and replace
Clean and lubricate the valve
and the valve cylinder with the
lubricant
provided
machine
Replace the o-rings
Find the seal and put it back in
place
Replace the damaged/worn seal
and check the condition of the
drive shaft
Assemble
the
main
correctly
Check the contacts and correct
those incomplete
Replace the gear motor
Replace or clean and lubricate
with the lubricant provided with
the machine
Check and correct