4
Technical description of the burner
4.1
Models available
Designation
RDB2.2 BX E15/21
RDB2.2 BX E21/26
RDB2.2 BX V15/26
RDB2.2 BX VC26
RDB2.2 BX V26/36
RDB2.2 BX V36/46
RDB2.2 BX VC36
4.2
Technical data
Model
Delivery
(1)
Heat output range
(1)
Thermal power
(1)
Fuel
Electrical supply
Motor
Capacitor
Ignition transformer
Pump (kerosene)
Electric power consumption
Protection level
Net weight
Model
Delivery
(1)
Heat output range
(1)
Thermal power
(1)
Fuel
Electrical supply
Motor
Capacitor
Ignition transformer
Pump (kerosene)
Electric power consumption
Protection level
Net weight
Reference conditions: Ambient temperature 20°C - Barometric pressure 1013 mbar - Altitude 0m a.s.l. (H i = 11.86 kWh/kg)
(1)
Values detected during operation.
(2)
20139038
Technical description of the burner
RDB2.2 BX E15/21
1.25
1.75 kg/h
15 - 21 kW
18 kW
Intensity 0.6 A – Output 90W - Speed 2800 tr/min. - 294 rad/s
(2)
RDB2.2 BX V26/36
2.17
3 kg/h
31 kW
31 kW
Intensity 0.6 A – Output 90W - Speed 2800 tr/min. - 294 rad/s
(2)
Voltage
1/230V/50Hz
1/230V/50Hz
1/230V/50Hz
1/230V/50Hz
1/230V/50Hz
1/230V/50Hz
1/230V/50Hz
RDB2.2 BX E15/26
1.75
2.17 kg/h
21 - 26 kW
23.5 kW
Kerosene, viscosity 1.6
~
Single-phase,
50Hz 230V ± 10%
4,5 F
Secondary 8 kV – 16 mA
Max. pressure; 10 bar 10 (145 PSI)
0,16 kW
IP 20
8.2 kg
RDB2.2 BX V36/46
3
3.83 kg/h
41 kW
41 kW
Kerosene, viscosity 1.6
~
Single-phase,
50Hz 230V ± 10%
4,5 F
Secondary 8 kV – 16 mA
Max. pressure; 10 bar 10 (145 PSI)
0,16 kW
IP 20
8.2 kg
8
GB
Code
20147321
20147346
20094977
20147322
20109931
20110334
20147350
RDB2.2 BX V15/26
RDB2.2 BX VC26
1.25
2.17 kg/h
15 - 26 kW
21 kW
2
6mm
/s at 20°C
RDB2.2 BX VC36
3.83 kg/h
36 kW
36 kW
2
6mm
/s at 20°C
Tab. A
2.17 kg/h
26 kW
26 kW
Tab. B