Riello RDB B10 Installation, Use And Maintenance Instructions
Riello RDB B10 Installation, Use And Maintenance Instructions

Riello RDB B10 Installation, Use And Maintenance Instructions

Gas oil burners, one stage operation

Advertisement

Quick Links

Installation, use and maintenance instructions
Gas oil burners
One stage operation
CODE
3515105
3515305
3515505
3515506
MODEL
RDB2.2R FIREBIRD 70D
RDB2.2R FIREBIRD 90D
RDB2.2R FIREBIRD 120D
RDB2.2R FIREBIRD 150D
TYPE
744T1R
744T3R
744T5R
744T5R
2903261 (5) - 10/2013

Advertisement

Table of Contents
loading

Summary of Contents for Riello RDB B10

  • Page 1 Installation, use and maintenance instructions Gas oil burners One stage operation CODE MODEL TYPE 3515105 RDB2.2R FIREBIRD 70D 744T1R 3515305 RDB2.2R FIREBIRD 90D 744T3R 3515505 RDB2.2R FIREBIRD 120D 744T5R 3515506 RDB2.2R FIREBIRD 150D 744T5R 2903261 (5) - 10/2013...
  • Page 2 Original instructions...
  • Page 3: Table Of Contents

    Contents Declaration....................................3 Information and general warnings............................4 Information about the instruction manual........................4 2.1.1 Introduction ..................................4 2.1.2 General dangers ................................4 2.1.3 Danger: live components ..............................4 Guarantee and responsibility ............................5 Guidance for the use of bio fuel blends up to 30% ......................5 2.3.1 Information and general instructions..........................
  • Page 4 Contents Maintenance programme ..............................21 9.2.1 Maintenance frequency ..............................21 9.2.2 Checking and cleaning ..............................21 10 Faults / Solutions ..................................22 3261...
  • Page 5: Declaration

    The quality is guaranteed by a quality and management system certified in accordance with UNI EN ISO 9001. Legnago, 28.01.2013 Executive Director Research & Development Director RIELLO S.p.A. - Burner Department RIELLO S.p.A. - Burner Department Mr. I. Zinna Mr. R. Cattaneo...
  • Page 6: Information And General Warnings

    Information and general warnings Information and general warnings Information about the instruction manual 2.1.1 Introduction 2.1.3 Danger: live components The instruction manual supplied with the burner: This symbol indicates operations which, if not car-  is an integral and essential part of the product and must not ried out correctly, lead to electric shocks with le- be separated from it;...
  • Page 7: Guarantee And Responsibility

    All components within the hydraulic circuit suitable for manual, operating negligence, incorrect installa- bio fuel use and supplied by Riello will be identified as Bio com- tion and carrying out of non authorised modifica- patible. No warranty is given in relation to the use of components...
  • Page 8: Information And General Instructions

    Bio fuel delivery. If this is not completed then due to the In no event shall Riello (and its subsidiaries) be liable for any in- hydroscopic nature of Bio fuel, it will effectively clean the...
  • Page 9: Safety And Prevention

    Safety and prevention Safety and prevention Introduction The burners have been designed and built in compliance with the type and pressure of the fuel, the voltage and frequency of the current regulations and directives, applying the known technical electrical power supply, the minimum and maximum deliveries for rules of safety and envisaging all the potential danger situations.
  • Page 10: Technical Description Of The Burner

    Technical description of the burner Technical description of the burner Technical data TYPE 744T1R 744T3R 744T5R Output – Thermal power 1.2 – 2.2 kg/h 1.8 – 3.5 kg/h 2.8 – 4.5 kg/h (with air at 20°C) 14.3 – 26.3 kW 21.5 –...
  • Page 11: Burner Dimensions

    Technical description of the burner Burner dimensions CF Version Flange Burner D4592 BF Version ø 75 S8266 Fig. 2 Firing rates The MAXIMUM OUTPUT is chosen from within the diagram area desired delivery and a horizontal line from the pressure in the (Fig.
  • Page 12: Installation

    Installation Installation Notes on safety for the installation After carefully cleaning all around the area where the burner will The installation of the burner must be carried out be installed, and arranging the correct lighting of the environ- by qualified personnel, as indicated in this manual ment, proceed with the installation operations.
  • Page 13: Installer/Servicer Notes For The Use Of Gas Oil With Bio Blends Up To 30

    30%" within the burner technical manual). be suitable for bio fuel use (check with Riello if in doubt).  If a Bio blend is in use the installer must seek information...
  • Page 14: Boiler Fixing

    Installation Boiler fixing  Put on the flange 1)(Fig. 6) the screw and two nuts.  Fix the flange 1) to the boiler door 4) using screws 2) and (if necessary) the nuts 3) interposing the insulating gasket 5)(Fig. 7). The seal between burner and boiler must be airtight.
  • Page 15 Installation The combustion air supply is through a flexible or rigid pipe con- nected to the air intake. Consequently, you must comply with the following requirements and instructions:  The combustion air intake tube must be: - fastened securely to the burner; - made of a suitable material, with temperature characteris- tics in the range - 30 °C to 80 °C;...
  • Page 16: Hydraulic Systems

    In case of use with gas oil containing up to 30% Bio blend, it will be essential to use flexible oil lines suitable for bio fuel use. WARNING Please contact Riello for further information. D10934 Fig. 13 Key (Fig. 13)
  • Page 17: One Pipe System

    Usually the tank is lower than the burner. You are advised to use additional filters on the fuel supply line. Riello recommends a good quality fuel filter at the CAUTION tank (Fig. 14 - Fig. 15) and a secondary filter (60 ...
  • Page 18: Two Pipe System

    You are advised to use additional filters on the fuel supply line. Riello recommends a good quality fuel filter at the CAUTION tank (Fig. 16) and a secondary filter (60  for gas oil and 15  for kerosene) are used to protect the burner pump and nozzle from contamination.
  • Page 19: Electrical System

    Electrical system Electrical system Notes on safety for the electrical wiring  The electrical wiring must be carried out with the electrical supply disconnected.  Electrical wiring must be carried out by qualified personnel and in compliance with the regulations currently in force in the country of destination.
  • Page 20: Electrical Wiring

    Electrical system Electrical wiring 7.2.1 Control box 50Hz - 230V This operation must be performed with the burner turned off and mains power disconnected. DANGER Main switch To remove the control box (Fig. 18) from the burner follow of the istruction: T6 A ...
  • Page 21: Start-Up, Calibration And Operation Of The Burner

    Start-up, calibration and operation of the burner Start-up, calibration and operation of the burner Notes on safety for the first start-up The first start-up of the burner must be carried out Check the correct working of the adjustment, com- by qualified personnel, as indicated in this manual mand and safety devices.
  • Page 22: Air Damper Adjustment

    Start-up, calibration and operation of the burner Air damper adjustment The settings indicated in the schedule are purely indicative. All these conditions may require a different air-damper setting. Each installation however, has its own unpredictable working conditions: actual nozzle output; positive or negative pressure in the combustion-chamber, the need of excess air, etc.
  • Page 23: Maintenance

    Maintenance Maintenance Notes on safety for the maintenance The periodic maintenance is essential for the good operation, Before carrying out any maintenance, cleaning or checking oper- safety, yield and duration of the burner. ations: It allows you to reduce consumption and polluting emissions and to keep the product in a reliable state over time.
  • Page 24 Faults / Solutions Faults / Solutions Here below you can find some causes and the possible solutions When lock out lamp lights the burner will attempt to light only after for some problems that could cause a failure to start or incorrect pushing the reset button.
  • Page 28 RIELLO S.p.A. I-37045 Legnago (VR) Tel.: +39.0442.630111 http:// www.riello.it http:// www.rielloburners.com Subject to modifications...

This manual is also suitable for:

Rdb2.2r firebird 70dRdb2.2r firebird 90dRdb2.2r firebird 120dRdb2.2r firebird 150d35151053515305 ... Show all