NECESSARY EQUIPMENT FOR INSTALLATION

Depending upon model, use the batteries and cables on the output terminals as specified in the following table:
MODEL
Battery voltage
Battery capacity
Minimum output cable size
Number of battery cells
MODEL
Battery voltage
Battery capacity
Minimum output cable size
(battery charger-junction "J")
Minimum output cable size
(junction "J" - battery)
Number of battery cells
MODEL
Battery voltage
Battery capacity
Minimum output cable size
(battery charger-junction "J")
Minimum output cable size
(junction "J" - battery)
Number of battery cells
For the single battery chargers, the wires connected to the output terminals must have a maximum length of 4 meters.
For the length of the output wires in case more battery chargers are connected in parallel (current sharing mode) refer to the diagram of Fig. 2B.
WARNING: the battery charger must be used only with re-chargeable lead/liquid electrolytic batteries (open or
sealed), Gel, AGM, Optima
WARNING: the battery charger can not be used to recharge non rechargeable batteries.

INSTALLATION SITE

Install the battery charger as close as possible to the batteries in a dry and airy
spot, to allow the correct operation of the device at full power.
The battery charger can be installed on a horizontal surface or vertical wall paying
attention that the output connector faces downwards.
In case of battery chargers connected in parallel (current sharing mode), install-
ing one next to the other.
The battery charger must be fixed to the support surface with screws strong
enough to support its weight, paying attention that they do not weaken or cause
cracks to the boat structure.
Vertical installation is recommended since the natural convection of the heat will
favour the cooling of the device.
The perimeter of the battery charger (excluding the support base) must be kept at
a distance from walls or objects by a minimum of 5 cm.
SBC 1100 NRG+ FR
SBC 1200 NRG+ FR
12 V
360 ÷ 600 Ah
450 ÷ 1000 Ah
25 mm
2
6
SBC 1100 NRG+ FR
SBC 1200 NRG+ HR
2 units in parallel
2 units in parallel
12 V
720 ÷ 1200 Ah
900 ÷ 2000 Ah
25 mm
2
50 mm
2
6
SBC 1100 NRG+ FR
SBC 1200 NRG+ HR
3 units in parallel
3 units in parallel
12 V
1080 ÷ 1800 Ah
1350 ÷ 3000 Ah
25 mm
2
95 mm
2
6
, Li-Ion.
®
SBC 1450 NRG+ HR
270 ÷ 600 Ah
35 mm
25 mm
2
SBC 1450 NRG+ HR
2 units in parallel
540 ÷ 1200 Ah
35 mm
25 mm
2
95 mm
50 mm
2
SBC 1450 NRG+ HR
3 units in parallel
810 ÷ 1800 Ah
35 mm
25 mm
2
150 mm
2
95 mm
INSTALLATION
SBC 1950 NRG+ HR
24 V
360 ÷ 800 Ah
35 mm
2
2
12
SBC 1950 NRG+ HR
2 units in parallel
24 V
720 ÷ 1600 Ah
35 mm
2
2
70 mm
2
2
12
SBC 1950 NRG+ HR
3 units in parallel
24 V
1080 ÷ 2400 Ah
35 mm
2
2
2
120 mm
2
12
5 cm
CONNECTOR
EN
SBC 2450 NRG+ HR
450 ÷ 1000 Ah
35 mm
2
SBC 2450 NRG+ HR
2 units in parallel
900 ÷ 2000 Ah
35 mm
2
95 mm
2
SBC 2450 NRG+ HR
3 units in parallel
1350 ÷ 3000 Ah
35 mm
2
150 mm
2
5 cm