Typical Installation – Suction Feed System
KEY
A
Hydraulic Fluid Control, 236–864
(See Manual 308–395)
B
Porous Plug (Weep tube optional)
C
Fluid Dispenser Outlet
D
Drain Valve (Required)
F
Hydraulic Return Line
G
Hydraulic Outlet, 3/4 npt
Fig. 1
The installation shown in Fig. 1 is only a guide. For
assistance in designing a system to suit your needs,
contact your Graco distributor.
Mount the pump to suit the type of installation planned.
See page 22 for Accessories.

Installation

F
K
M
N
J
S
H
Return Line Shutoff Valve
J
Hydraulic Inlet, 3/8 npt
K
Hydraulic Supply Line Shutoff
Valve
L
Pressure Gauge
M
Pressure Reducing Valve
N
Flow Control Valve
P
H
A
L
G
R
C
B
D
Q
P
Hydraulic Supply Line (Use only
GRACO hydraulic power supply)
Q
Material Supply
R
Ground Wire (Required)
S
Wall Mounting Bracket 236–778
(See Manual 308–394)
WARNING
Maximum Working Pressure of Accessories
To reduce the risk of serious bodily injury including
fluid injection and splashing in the eyes or on the
skin, which may be caused if a component rup-
tures, all accessories added to the reciprocator
power supply side must have at least a 1500 psi
(10 MPa, 103 bar) maximum working pressure and
those to the pump fluid outlet side must have at
least a 375 psi (2.6 MPa, 26 bar) maximum
working pressure.