5-2. ERROR CODES AND
WARNINGS (Continued)
Display
"E-41 SYSTEM DATA LOST"
"E-46 DATA SAVE FAILED"
"PLEASE DE-LIME
WATER PAN"
"WATER PAN NOT FILLING,
CHECK WATER SUPPLY"
803
Cause
• Memory Scrambled
• Memory Scrambled
• Water pan needs
cleaned
• Water supply shut-off;
solenoid clogged or
faulty
Panel Board Correction
• Turn switch to OFF position, then back to
ON; if the display shows "E-41", the
control should be re-initialized (see Pro-
gramming Section); if "E-41"persists, have
PC board replaced
• Turn switch to OFF position, then back to
ON; if the display shows "E-46", the
control should be re-initialized (see Pro-
gramming Section); if "E-46"persists, have
PC board replaced
• Follow the weekly cleaning procedures;
this warning will not shut down the heat
or humidity; if "PLEASE DE-LIME
WATER PAN" persists, have PC board
replaced
• Check water shut-off valve; clean or
replace solenoid; this warning won't shut
down the heat or humidity