3-5. CLEANING
PROCEDURES (Continued)
Figure 3-4
Figure 3-5
3-5
4.
Wipe the control panel with a damp cloth. Do not
splash water around controls.
5.
Reinstall racks, and leave a door partially open over
night to allow interior cabinet to thoroughly dry.
Weekly:
1.
Remove pans and racks from cabinet.
2.
Disconnect water supply at side of cabinet. Open drain
valve and empty water pan into a shallow pan or floor
drain. Figure 3-4.
HOT WATER! Do not place your hand under the
drain while draining the unit. Failure to follow this
warning could result in severe burns and injury.
3.
Remove concentration ring assembly from water pan.
Figure 3-5.
Concentration ring could be HOT! Allow to cool
before removing, or burns could result.
4.
Wash the concentration ring in a dishwasher or sink.
5.
Liberally spray the water pan with a concentrated
deliming agent and let stand for 10 minutes.
6.
Scrub the pan with a brush and flush with water.
7.
Return the concentration ring assembly to the water
pan.
8.
Reinstall the racks and pans.
9.
Unit is now ready for use.