Typically, when a system is in sleep mode, you cannot
communicate with the modules. In sleep mode, the system
consumes minimal power and may dissipate less heat than it does
in normal mode. Refer to the
information about power consumption and thermal dissipation.

Cable Requirements for EMC Compliance

Select and install cables for the NI 9503 in accordance with the
following requirements:
Do not tie the motor case to the NI 9503 chassis ground.
Use only shielded cables to connect the NI 9503 to a motor and
a power supply.
Terminate the motor and power supply cable shields to the
COM terminal of the NI 9503. In addition, terminate the cable
shields at the other end to either earth ground or the chassis of
the connected motor and/or power supply.