Dc Fuse Replacement; Fuse Ratings - Avtech AVR-E2-B-P-TEK1C Instructions Manual

+10 to +50 volts, nanosecond rise time high performance pulse generator with ieee 488.2 / rs-232 / ethernet control
Table of Contents

Advertisement

DC FUSE REPLACEMENT

The DC fuses may be replaced by inserting the tip of a flat-head screwdriver into the
fuse holder slot, and rotating the slot counter-clockwise. The fuse and its carrier will
then pop out.

FUSE RATINGS

The following table lists the required fuses:
Nominal
Fuses
Mains
Voltage
#1, #2 (AC) 100-240V
#3 (DC)
N/A
#4 (DC)
N/A
The recommended fuse manufacturer is Littelfuse (http://www.littelfuse.com).
Replacement fuses may be easily obtained from Digi-Key (http://www.digikey.com) and
other distributors.
Rating
Case Size
0.5A, 250V,
5×20 mm
Time-Delay
1.6A, 250V,
5×20 mm
Time-Delay
0.5A, 250V,
5×20 mm
Time-Delay
Recommended Replacement Part
Littelfuse Part
Digi-Key Stock
Number
0218.500HXP
021801.6HXP
0218.500HXP
14
Number
F2416-ND
F2424-ND
F2416-ND

Advertisement