10-2-9 Outdoor Discharge over temperature error
Indoor display
3-LED DISPLAY
LED1
LED2
Outdoor display
LED ON
LED BLINKING
1. Checklist :
1) Check the discharge temperature in the outdoor unit
2) Check the compressor locking or gas leak
3) Download the EEPROM data
2. Troubleshooting procedure
Restart after power o .
Is the discharge over
temperature sensor error appeared
The condition is too poor for
air conditioner to operate .
Wait until discharge temperature is decreased
Restart after power o
Is the discharge over temperature
sensor error appeared again?
Download the EEPROM data
Is the discharge over temperature
sensor error appeared again?
Exchange the Outdoor PBA
Exchanged the Compressor
10-10
LED3
LED OFF
after 30min ~ 1Hr
again?
YES
YES
YES
7-SEG DISPLAY
E416
Outdoor Discharge ove temperature error
Outdoor Discharge over temperature error
NO
Terminate the service
NO
Terminate the service
NO
Terminate the service
DESCRIPTION
Samsung Electronics