Maytag MDG120PVV Installation Manual page 27

Phase 7/non-coin with s.a.f.e.
Hide thumbs Also See for MDG120PVV:
Table of Contents

Advertisement

2. Electrical Service Specifications
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT:
208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
NOTES:
A.
When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY.
Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to listed
appliance amp draw data.
B.
Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY. For others, calculate/verify correct
breaker size according to appliance amp draw rating and type of breaker used.
C.
Circuit breakers for 3-phase (3Ø) dryers must be 3-pole type.
SERVICE
PHASE
VOLTAGE
208
230/240
380-400
416
460/480
575
* AWG Stranded Wire Type...size wire as per National Electrical Code or local codes.
** 3-Wire is available.
IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is
affixed to the left side panel/wall area behind the control door. In the case of 208
VAC or 230/240 VAC, the supply voltage must match the electric service
specifications of the data label exactly.
WARNING: 208 VAC AND 230/240 VAC ARE NOT THE SAME. Any damage done to dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
NOTE: Manufacturer reserves the right to make changes in specifications at any time without notice or
obligation.
APPROX.
WIRE
AMP DRAW
SERVICE
60 Hz
50 Hz
3
14.5
3
14.6
17.4
4**
8.7
4**
8.4
3
7.8
3
5.8
MINIMUM
WIRE SIZE
60 Hz
*
20
*
20
*
*
*
*
23
FUSING
CIRCUIT
Dual Element
BREAKER
Time Delay
50 Hz
60 Hz
20
25
20
15
15
15
15
15
15
50 Hz
25
15
15
9/4/03