EMC Performance of Cables and Connectors Snell products are designed to meet or exceed the requirements of the appropriate European EMC standards. In order to achieve this performance in real installations it is essential to use cables and connectors with good EMC characteristics.
Information in this manual and software are subject to change without notice and does not represent a commitment on the part of Snell Ltd. The software described in this manual is furnished under a license agreement and may not be reproduced or copied in any manner without prior agreement with Snell Ltd. or their authorized agents.
In addition, the product handles embedded, AES (balanced or unbalanced) and analog audio, with a range of additional features such as Aspect Ratio Conversion (ARC) and color space conversion. The CVR800 has a DC input for redundant PSU capability and is provided in a compact half rack width housing with remote control via an Ethernet connection.
Page 13
(minimum) and 2 fields plus 0.4 ms (maximum). For ARC mode, there must be at minimum 4 fields of delay as the CVR800 must load at least 3 fields of data to be able to do the aspect ratio conversion with 'still mode' processing. In input-locked mode, the ARC delay could be just 4 fields. However, if the user is synchronizing the output to a chosen reference, as in Sync mode above, depending on the reference, and up to an additional 2 fields + 1ms (maximum) delay may be incurred.
Operation via the Web Interface In addition to the unit front controls, the CVR800 can also be controlled by means of a Web interface accessed via the 10/100 BaseT Ethernet connection. Connection to the Web interface can either be made directly or via a DHCP network.
Appendix A: (Automated Aspect Ratio Control) Recognized Input Signalling The CVR800 can be configured to respond automatically to a variety of Aspect Ratio signalling standards, controlling both the ARC conversion that is performed, and the new signalling that can be inserted at the unit’s video outputs.
Screen shots used to illustrate the upgrade procedure in the appendix refer to Mach HD. If you are upgrading CVR800 or TBS800 please note that the software references will be to CVR800 or TBS800 respectively. This diagram illustrates the basic connection process: To perform an upgrade of any of the listed units, perform the following procedure.
Mach-1 The RollTop application is available free of charge from the Snell Service department. Please contact your local Snell Sales office for more information about the other RollCall applications and services mentioned. Note: Kudos+Plus products that connect through RollTop – USB Gateway, or RollTop – IPI Gateway do NOT support control from RollPod, RPAN, IQSPI or IQCGPI products.
Page 80
To connect to a USB enabled unit (TBS150, CVR400, TBS190, CVR600), see page 86. • To connect to an IP enabled unit (CVR700, TBS700, CVR800, TBS800, Mach HD), see page 88. Finally, the Log Server to be used (if required) can be specified. See page 91.
Page 94
Product Support Procedure If you experience any technical or operational difficulties with a Snell product please do not hesitate to contact us or utilize our online form to request assistance. There is a lot of information you can give us that will enable us to diagnose your problem swiftly. Please read the following guidelines, as these suggestions will help us to help you.