Snell IQQMD00 User Instruction Manual

Quad-link-sdi down converter for ultra hd signals

Advertisement

Quick Links

User Instruction Manual
IQQMD00
Quad-link-SDI Down Converter for Ultra HD Signals
snellgroup.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IQQMD00 and is the answer not in the manual?

Questions and answers

Summary of Contents for Snell IQQMD00

  • Page 1 User Instruction Manual IQQMD00 Quad-link-SDI Down Converter for Ultra HD Signals snellgroup.com...
  • Page 2: Table Of Contents

    6.6.3 Logging Misc ..........27 Issue 1 Rev 1 Page 2 © 2015 Snell Limited...
  • Page 3 6.8.3 Restart ........... . . 31 Issue 1 Rev 1 Page 3 © 2015 Snell Limited...
  • Page 4: About This Manual

    Information in this manual and software are subject to change without notice and does not represent a commitment on the part of Snell Limited. The software described in this manual is furnished under a license agreement and may not be reproduced or copied in any manner without prior agreement with Snell Limited or their authorized agents.
  • Page 5: Introduction

    Introduction 2. Introduction The IQQMD00 provides conversion for Quad-link Ultra HD SDI inputs to SDI outputs in 1080p, 1080i, 720p or SD formats. This allows Ultra High Definition signals to be integrated into existing HD/SD-SDI workflows and monitored on standard 1920 x 1080 displays removing the need for expensive Ultra HD specific equipment and monitors.
  • Page 6: Order Codes

    Fiber SFP type must be ordered in addition to the module. Note: 2.3 Rear Panel View This section contains the available rear panels. 2.3.1 IQQMD0000-1A3, IQQMD0000-1B3 Fig 2. IQQMD0000-1A3, IQQMD0000-1B3 Issue 1 Rev 1 Page 6 © 2015 Snell Limited...
  • Page 7: Enclosures

    IQQMD00 www.snellgroup.com Introduction 2.4 Enclosures IQQMD00 can only be fitted in the following enclosures, shown below: IQH3B-S-0, IQH3B-S-P Fig 3. IQH3B-S-0, IQH3B-S-P IQH1A-S-P Fig 4. IQH1A-S-P IQH3A-S-0, IQH3A-S-P Fig 5. IQH3A-S-0, IQH1A-S-P IQH3A-E-0, IQH3A-E-P, IQH3A-0-P Fig 6. IQH3A-E-0, IQH3A-E-P, IGH3A-0-P IQH1A-S-P Fig 7.
  • Page 8: Feature Summary

    IQQMD00 www.snellgroup.com Introduction 2.5 Feature Summary The IQQMD00 Quad-link-SDI Down Converter for Ultra HD Signals provides the following features: • Custom scaling and filtering to provide seamless reconstruction of a quad-link • UHD input for HD single link applications •...
  • Page 9: Technical Specification

    3.1 Inputs and Outputs Inputs and Outputs Signal Inputs Inputs Connector/Format BNC / 75 Ohm panel jack on standard Snell connector panel Input Cable Length Up to 100m Belden 1694A @ 3Gbps Return loss >-10 dB 1.5GHz to 3GHz Signal Outputs Outputs 1 x BNC &...
  • Page 10: Rollcall Features

    Version Numbers Uptime Rear ID Rear Status Slot Width Slot Start Power usage Module IDs Licensed Options RollTrack Controls On/off, Index, Source, Address, Command, Status, Sending Table 3 RollCall Features Issue 1 Rev 1 Page 10 © 2015 Snell Limited...
  • Page 11: Specifications

    IQQMD00 www.snellgroup.com Technical Specification 3.4 Specifications Specifications Conversion Delay 2 input frames Start-up Time 28 seconds Power consumption Module Power 22.5W/20.5PR Consumption Table 4 Specifications Issue 1 Rev 1 Page 11 © 2015 Snell Limited...
  • Page 12: Connections

    This section contains information on the module connectors. 4.1 SDI Inputs Fig 8. SDI Output 4.2 SDI Output Fig 9. SDI Input 4.3 GPIO Fig 10. GPIO 4.4 SFP Fig 11. SFP Issue 1 Rev 1 Page 12 © 2015 Snell Limited...
  • Page 13: Card Edge Leds

    Indicates that the respective power supply is present. OK (Green) Indicates that the respective power supply is present. OK (Green) Flashes to indicate that the CPU is working/active. Table 5 Card Edge LEDs Issue 1 Rev 1 Page 13 © 2015 Snell Limited...
  • Page 14 This LED is briefly illuminated in transitional states like standard changes. GOOD OK (Green) Indicates that the module is operating correctly. Table 5 Card Edge LEDs Issue 1 Rev 1 Page 14 © 2015 Snell Limited...
  • Page 15: Rollcall Control Panel

    Post fixed with an A to indicate 1080/59pA, 1080/50pA Level-A. If the Reference is OK, displays FAIL state OK and the Standard (for example, 1080/59pA) of the reference Table 6 Video input and output summary Issue 1 Rev 1 Page 15 © 2015 Snell Limited...
  • Page 16: Video Input Status

    Post fixed with an A to indicate 720/50p, 1080/59pA, Level-A 1080/50pA WARN:FreeRun Selected reference source or freerun (No Reference Lock) No reference present or OK_(Ref standard) FAIL Table 8 Video output status Issue 1 Rev 1 Page 16 © 2015 Snell Limited...
  • Page 17: Video

    In SMPTE mode, each input is pixel multiplexed so if you present the same ordinary 4k signal into each input, it always appears as a single picture. Table 9 Inputs Issue 1 Rev 1 Page 17 © 2015 Snell Limited...
  • Page 18: Outputs

    Displays the status and video standard of the video outputs. Table 10 Outputs 6.2.3 References The following options enable you to control and monitor the reference inputs: Fig 20. References Issue 1 Rev 1 Page 18 © 2015 Snell Limited...
  • Page 19 Reference 1 Source - Lock to Input 1 / Lock to Input 2 / Lock to Input 3 / Lock to Input 4 / Frame Ref A / Frame Ref B Table 11 References Issue 1 Rev 1 Page 19 © 2015 Snell Limited...
  • Page 20: System Gpio

    Driving the GPI output High (+5V typical) Status Displays the GPIO status. Invert Configure the GPI to be active low when it is an Output. Table 12 GPIO configuration Issue 1 Rev 1 Page 20 © 2015 Snell Limited...
  • Page 21: Gpi

    Configures the Monitor output to be in HDMI mode (If suitable SFP is fitted). Monitor out DVI Configures the Monitor output to be in HDMI mode (If suitable SFP is fitted). Table 13 GPI Fig 24. Electrical interface Issue 1 Rev 1 Page 21 © 2015 Snell Limited...
  • Page 22: Gpo

    No User Mem Sel'd Operates to warn that no User Memory has been selected. Table 14 GPO The GPI outputs have one configuration box. If you select Unused, the GPI output is Note: inactive. Issue 1 Rev 1 Page 22 © 2015 Snell Limited...
  • Page 23: Memories

    Last Recalled Memory. Memories do not recall RollTracks, GPIO's or log field states, for example, whether a log Note: value is enabled or disabled. Issue 1 Rev 1 Page 23 © 2015 Snell Limited...
  • Page 24: Savesets

    To restore a file, from the Connected Units pane, select the folder icon (8th from the left). Fig 29. Restoring a saveset The user is then prompted to either select a local Saveset or a previously saved file. Issue 1 Rev 1 Page 24 © 2015 Snell Limited...
  • Page 25: Logging

    INVALID - The input standard in invalid. INPUT_N_STANDARD The detected input standard OUTPUT_1_MONITOR_TYPE The type of output video signal OUTPUT_1_STANDARD The selected output standard SFP_1_STATE Reports the presence of the SFP Table 15 Logging - Video Issue 1 Rev 1 Page 25 © 2015 Snell Limited...
  • Page 26: Logging - System

    The Logging - System screen enables the user to select the fields for the system related log. Fig 31. Logging - System The following field is available: Name Description PROCCARD_TEMPERATURE_FPGA OK:xxC - where xx is the temperature in °C Table 16 Logging - System Issue 1 Rev 1 Page 26 © 2015 Snell Limited...
  • Page 27: Logging Misc

    Displays the primary IO module ID IOMOD2_ID= Not relevant for this product PROCMOD_ID= Displays the processing card ID LICENSED_OPTIONS= Displays the options included in the license Table 17 Logging - Misc Issue 1 Rev 1 Page 27 © 2015 Snell Limited...
  • Page 28: Rolltrack

    Frame reference is Lost Ref 1 OK Reference is OK Ref 1 Lost Reference is Lost Ref N ####_##P/I Present line and frame rate standard on reference Table 18 RollTrack Source Issue 1 Rev 1 Page 28 © 2015 Snell Limited...
  • Page 29: Rolltrack Address

    A message appears here when the unit is actively sending a RollTrack command. The following messages can appear: Message Description The message is not being sent. The message is being sent. Table 19 RollTrack Sending Issue 1 Rev 1 Page 29 © 2015 Snell Limited...
  • Page 30: Rolltrack Status

    RollTrack message has not been correctly acknowledged at the destination unit. This could be because the destination unit is not of the type specified. Disabled RollTrack sending is disabled. Table 20 RollTrack Status Issue 1 Rev 1 Page 30 © 2015 Snell Limited...
  • Page 31: Setup

    The Default Settings button enables the module settings to be reset to their factory defaults but does not affect the user memories. 6.8.3 Restart The Restart button enables the module to be rebooted. Issue 1 Rev 1 Page 31 © 2015 Snell Limited...

Table of Contents