Victron energy SmartSolar SCC900650010 Manual page 12

Control display
Table of Contents

Advertisement

Nu
mb
Scrolling text
er
LOW
30
TEMPERATURE
LEVEL
31
BMS PRESENT
35
LOAD MODE
LOAD LOW
36
VOLTAGE
LOAD HIGH
37
VOLTAGE
MAXIMUM
40
EQUALIZATION
TIME
EQUALIZATION
41
AUTO STOP
EQUALIZATION
42
CURRENT
PERCENTAGE
BACKLIGHT
49
INTENSITY
BACKLIGHT
50
ALWAYS ON
51
SCROLL SPEED
Page 10
SmartSolar Control display manual
LCD
Sets low temperature level at which charging has to stop (°C or
°F).
Sets if BMS is present (Y or N).
This setting is automatically set to Y when a compatible BMS is
detected.
To revert the solar charger to normal operation (without BMS) set
manually to N. For example if the charger is moved to another
location were a BMS is not needed.
Sets the load control mode the relay (setting 11, value 10) or the
VE.Direct port (setting 58, value 4) is using to control a load:
• 0 - Load output always off
• 1 - Batterylife algorithm (default)
• 2 - Conventional algorithm 1 (off 22.2V, on 26.2V)*
• 3 - Conventional algorithm 2 (off 23.6V, on 28.0V)*
• 4 - Load output always on
• 5 - User defined algorithm 1 (off 20.0V, on 28.0V)*
• 6 - User defined algorithm 2 (off 20.0V, on 28.0V)*
* Settings are for 24V systems, for 12V systems devide by 2, for
24V systems multiply by 2.
Sets the load low voltage (V).
Sets the load high voltage (V).
Sets the maximum automatic equalization time (h).
Sets if the equalization should stop when the equalization voltage
(setting 8) has been reached (Y or N).
Sets the equalization current as a percentage (%) of the maximum
charge current setting entered in setting 2.
This setting can only be changed when the charge algorithm has
been set to USER in setting 4.
Sets the display's back light intensity level (1to10).
Sets when the back light should turn off after the last keypress:
• ON - Back light is always on.
• OFF - Back light turns off 60 seconds after the last keypress.
• AUTO - Back light is only on when the solar charger is charging.
Sets the scroll speed (1 to 5).
Desription and notes
Do not set to Y when a BMS is connected to
the solar charger's remote on/off terminal.
Operation

Advertisement

Table of Contents
loading