Advertisement

Any settings change via the display or the VictronConnect App will override the rotary switch setting. Turning
the rotary switch will override settings made with the display or via the VictronConnect App.
All available settings are indicated in below table, in the order they appear when scrolling through the menu, together with a basic
description and notes for each setting. For the full description of the solar charger settings refer to the solar charger manual.
Nu
mb
Scrolling text
er
01
POWER ON OFF
MAXIMUM
02
CHARGER
CURRENT
BATTERY
03
VOLTAGE
CHARGE
04
ALGORITHM
ABSORPTION
05
VOLTAGE
06
FLOAT VOLTAGE
EQUALIZATION
08
VOLTAGE
AUTOMATIC
09
EQUALIZATION
MANUAL
10
EQUALIZATION
Page 8
SmartSolar Control display manual
LCD
This setting turns the charger in the solar charger ON or OFF.
Sets the maximum charge current (A).
Sets the system voltage 12, 24, 36 or 48V.
Sets the charge algorithm.
A preset charge algorithm has been selected via the rotary switch.
This setting toggles between the preset algorithm or a USER
defined algorithm.
Only when the USER algorithm has been selected, the charge
settings in the remainder of the setup menu can be changed.
Sets the absorption voltage (V).
This setting can only be changed when the charge algorithm has
been set to USER in setting 4.
Sets the float voltage (V).
This setting can only be changed when the charge algorithm has
been set to USER in setting 4.
Sets the equalization voltage (V).
This setting can only be changed when the charge algorithm has
been set to USER in setting 4.
Sets if an automatic equalization should take place and how often
this should be. Set to OFF 0 (default) or a number between 1
(every day) and 250 (once every 250 days).
Initiates a manual equalization (START, STOP).
Only perform a manual equalisation during absorption or float
charge stage, and when there is sufficient sunlight.
Press SELECT: the text START will blink, press SELECT again to
start equalisation.
The manual equalise duration is 1 hour.
To terminate the equalisation mode prematurely, enter the setup
menu and navigate to setup item 10, press SELECT: the text
STOP will blink, press SELECT again to stop equalisation.
Desription and notes
Do not equalize charge Gel, AGM, VRLA
or lithium batteries. Equalization can cause
damage to the battery if the battery is not
suitable for an equalization charge. Always
check with the battery manufacturer prior to
enabling equalization.
Do not equalize charge Gel, AGM, VRLA
or lithium batteries. Equalization can cause
damage to the battery if the battery is not
suitable for an equalization charge. Always
check with the battery manufacturer prior to
enabling equalization.
Operation