Troubleshooting - Pelgrim OVG260 Manual

Hide thumbs Also See for OVG260:
Table of Contents

Advertisement

Available languages

Available languages

TROUBLESHOOTING

Problem:
Appliance is connected
to the power mains but it
does not work.
Cooling system operates
continuously for a long
period of time:
Build-up of ice or frost in
the freezer interior may be
a result of the following:
Water leaking from the
refrigerator:
Signal light D is flashing:
Door is difficult to open:
Occurrence of murmur
after closing the door:
If none of the instructions above fixes your problem, call the nearest authorized service
center and state the type, model, and serial number found on the rating plate/label which is
located in the appliance interior.
Cause or remedy:
• Make sure there is voltage in the power outlet and that
the appliance is switched on.
• Too high environment temperature.
• Door opened too frequently or too long.
• Door not closed correctly (possible impurities on the
seal, misaligned door, damaged seal etc.).
• Too much fresh food inserted at once.
• Insufficient compressor and condenser unit cooling.
Clean the condenser unit.
• Door opened too frequently or too long.
• Door not properly closed.
• Poor door sealing.
• If the seal is dirty or damaged, clean or replace it.
• Clogged water discharge opening or water dripping past
the water gutter.
• Clean the clogged opening, for example using a plastic
straw.
• If a thick layer of ice builds up, defrost the appliance
manually (see Defrosting the Appliance).
• Frequent opening of the door, door open too long.
• Door not closed properly (particle between door gasket,
sagged door, damaged gasket, etc...).
• Excessively long power failure.
• Excessive quantity of fresh food inserted at once.
• If you are trying to open the freezer door after just
having closed it, this could be difficult to do.
As you open the door, some cool air escapes from
the appliance and it is replaced by warm air from the
environment. When this air is cooled, negative pressure is
generated which results in problems as you try to open
the door. After a few minutes, the condition is normalized
and the door can be easily opened again.
• After closing the door, some murmur can occur.
This phenomenon is normal and is due to pressure
equalisation.
21

Advertisement

Table of Contents
loading

Table of Contents