INSTALLATION AND CONNECTION

SELECTING THE ROOM
• Install the appliance in a dry and well ventilated room. The appliance will operate correctly
if the environment temperature is in the interval specifi ed in the table. The appliance class is
indicated on the rating plate / label with the basic information on the appliance.
Description
Extended temperate
Temperate
Subtropical
Tropical
Warning: Make sure the room where the appliance is installed is large enough. There
should be at least 1 m
on the rating plate in the appliance interior.
APPLIANCE PLACEMENT
• The appliance has four height-adjustable feet that allow setting the appliance height
between 82 cm and 90 cm.
Set the appliance height before installing it in the opening in the kitchen cabinetry.
Appliance height should be set so that the upper edge of the appliance is just under the
worktop (see Installation Instructions)
• Do not expose the appliance to direct sunlight and do not place it near sources of heat.
If this cannot be avoided, install an insulation panel.
CONNECTING THE APPLIANCE
• Connect the appliance to the power mains using a connection cable. The wall outlet
should be fi tted with a ground contact (safety socket). Nominal voltage and frequency
are indicated on the rating plate/label with basic information on the appliance.
• The appliance must be connected to the power mains and grounded in compliance
with the eff ective standards and regulations. The appliance will withstand short-term
deviations from the nominal voltage, but not more than +/- 6%.
12
Class
Ambient temperature range °C
SN
N
ST
T
3
of space per 8 grams of refrigerant. Amount of refrigerant is stated
+10 to +32
+16 to +32
+16 to +38
+16 to +43
Relative humidity
 75%