7 Maintenance
3x
30
Remove and empty the water tank�
T
Completely dissolve 3 JURA descaling tablets in a receptacle
T
holding 600 ml of water� This may take several minutes�
Pour the solution into the empty water tank and insert it into
T
the machine�
'Press the Rotary Switch'
Place a receptacle under the hot-water spout and dual spout�
T
Press the Rotary Switch�
T
'Machine is being
descaled', water flows straight into the drip
tray and out of the hot-water spout and dual spout repeatedly�
'Empty drip
tray'�
Empty the drip tray and coffee grounds container and put them
T
back into the machine�
'Fill water tank'
Empty the receptacle and place it under the hot-water and dual
T
spouts�
Remove the water tank and rinse it thoroughly�
T
Fill the water tank with fresh, cold water and reinsert the tank�
T
'Press the Rotary Switch'
Press the Rotary Switch�
T
Water flows straight into the drip tray and out of the hot-water
spout and dual spout repeatedly�
'Empty drip tray'
Empty the drip tray and coffee grounds container and put them
T
back into the machine�
E If the descaling operation stops unexpectedly, rinse the
water tank thoroughly�