Design And Installation Considerations; Selecting Fireplace Locations - Majestic BE36 Installation Manual

Hide thumbs Also See for BE36:
Table of Contents

Advertisement

B. Design and Installation Considerations
NOTICE:
Check building codes prior to installation.
Installation MUST comply with local, regional, state and
national codes and regulations.
Consult insurance carrier, local building inspector, fire
officials or authorities having jurisdiction over restrictions,
installation inspection and permits.
Before installing, determine the following:
-
Where the fireplace is to be installed.
-
The vent system configuration to be used.
-
Gas supply piping.
-
Electrical wiring.
-
Framing and finishing details.
Note: A raised hearth extension built flush
with the fireplace opening or less than 4
in. (102 mm) below the fireplace opening
requires the fireplace be installed on a non-
combustible surface.
-
Whether optional accessories - devices such as a
fan, wall switch or remote control - are desired.

1. Selecting Fireplace Locations

This fireplace may be used as a room divider, installed
along a wall, across a corner or used in an exterior chase.
See Figure 2.2.
F
E
Note: Measurements are FRAMING dimensions only and do
not include drywall either in the cavity or on the interior walls.
Model
inches
BE-36
mm
inches
BE-42
mm
Figure 2.2
Fireplace Locations
6
Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev J • 09/18
G
Across a
A
C
corner
H
As a
room
divider
D
A
48 in.
(1219 mm)
minimum
A
B
C
42
50
67 7/8
1067
1270
1724
48
56
73 7/8
1219
1422
1876
Locating the fireplace in a basement should be avoided.
Locating near frequently opened doors, central heat outlets
or returns, or other locations of considerable air movement
can affect the performance.
Consideration should be given to these factors before de-
ciding on a location.
NOTICE:
In addition to these framing dimensions, also
reference the following section:
Clearances (Section 3).
NOTICE:
• Illustrations and photos reflect typical installations and
are FOR DESIGN PURPOSES ONLY.
Illustrations/diagrams are not drawn to scale.
Actual installation/appearance may vary due to individual
design preference.
Hearth & Home Technologies reserves the right to alter
its products.
NOTICE:
A minimum 1/2 in. air clearance at the back and
sides of the fireplace assembly must be main-
tained.
Chimney sections at any level require a 2
in. minimum air space clearance between
the framing and chimney sections.
A
B*
I
In an exterior chase
or projecting into a
garage
Along a wall
I
B
A
D
E
F
59 1/2
34
14
1511
864
356
65 1/2
37 1/4
17
1664
946
432
H
Note:
1/2 in. (13 mm) min. air
space from fireplace to
combustible materials.
* 8 in. (203 mm) extra space
included for outside air
connection. If outside air duct
has no bend, this dimension
may be reduced as long as
minimum clearances are met.
1/2 in. (13 mm) all
configurations
H
G
H
I
48
21 1/2
12 in. (305 mm)
Minimum from FP
1219
546
opening to any
52 1/4
21 1/2
perpendicular wall.
1327
546