B. Design and Installation Considerations
NOTICE:
Check building codes prior to installation.
• Installation MUST comply with local, regional, state and
national codes and regulations.
• Consult insurance carrier, local building inspector, fire
officials or authorities having jurisdiction over restrictions,
installation inspection and permits.
Before installing, determine the following:
- Where the fireplace is to be installed.
- The vent system configuration to be used.
-
Gas supply piping.
-
Electrical wiring.
- Framing and finishing details.
- Whether optional accessories - devices such as a
fan, wall switch or remote control - are desired

1. Selecting Fireplace Locations

This fireplace may be used as a room divider, installed
along a wall, across a corner or used in an exterior chase.
See Figure 2.2.
Locating the fireplace in a basement should be avoided.
Locating near frequently opened doors, central heat
outlets or returns, or other locations of considerable air
movement can affect the performance.
E
D
As a
room
divider
92 in.
(2337 mm)
48 in.
(1219 mm)
MINIMUM
Model #
ASH50
Figure 2.2
Fireplace Locations
6
F
Across a
B
C
corner
G
B
A
in.
85 7/8
61 7/8
mm
2181
Majestic • Ashland ASH50 Installation Manual • 4059-900 • Rev E • 04/19
Consideration should be given to these factors before
deciding on a location.
NOTICE: In addition to these framing dimensions, also
reference the following section:
• Framing and Clearances (Section 3).
NOTICE:
• Illustrations and photos reflect typical installations and
are FOR DESIGN PURPOSES ONLY.
Illustrations/diagrams are not drawn to scale.
Actual installation/appearance may vary due to individual
design preference.
Hearth & Home Technologies reserves the right to alter
its products.
NOTICE:
A minimum 1-1/2 in. air clearance at the back and
sides of the fireplace assembly must be main-
tained.
Chimney sections at any level require a 2 in.
minimum air space clearance between the
framing and chimney sections.
B
A*
In an exterior chase
or projecting into a
garage
24 in. (610 mm)
from fireplace opening to
any perpendicular wall
Along a wall
A
B
B
C
D
103 1/4
51 5/8
1572
2623
1311
Note:
1-1/2 in. min. air space
from fireplace to
G
combustible materials.
1/2 in. min. air space at
nailing flanges.
* 12 in. (305 mm) extra space
included for each outside air
connection. If outside air duct has
no bend, this dimension may be
reduced as long as minimum
clearances are met.
1/2 in. (13 mm) all
configurations
G
E
F
25 1/4
73
28 1/2
641
1854
724
G