Air chipping hammer – 150 mm
Table of Contents

Advertisement

▪ Do not use abrasive or aggressive chemicals as benzene or thinner,
which may dissolve plastic parts.
▪ Do not allow liquids to enter the unit and never immerse it into liquids.
Water in the compressed air inlet can damage the machine. Therefore it
is recommended to drain the air lines and the compressor regularly! The
air filters should be cleaned at least once a week.

Lubrication

Pneumatic tools have to be lubricated always sufficiently. This is done
continuously and safest by using an oil-fog lubricator. If the oiler is
mounted centrally at the compressor or mounted firmly at the end of the
compressed-air pipe installation, use only a hose with a length of max. 10
m. If the hose is longer, the nebulisation disappears in the air. The oil
floats inside the hose and does not arrive at the air tool.

Oiler Setting

Hose up to 5 m every 2 minutes 1 drop
Hose up to 10 m every minute 1 drop
If you do not have an oiler at yours disposal, please put a few drops of oil
into the compressed-air connection (5) before every machine usage.
Lubricate the air chipping hammer once more after use, especially if you do
not operate the unit for a long time. Further maintenance work is not
necessary.

Storing

▪ Store the unit indoors in dust and dirt-free location, between 10° C and
30° C.
▪ Keep the unit out of reach of children and persons in need of supervi-
sion.
Operating
12