8   ERROR CODES
Error code
Description
Err 216
Over output current
The output amps over design limitation.
Action:
1. Make sure that you are not exceeding the rated data for the power source.
2. Turn OFF the power source and wait a few minutes.
3. Set the power source to the rated output voltage & current, If the error code
persist, retrieve the service log.
Err 311
Over output current for wire feeder
The wire feeder motor amps over design limitation.
Action:
1. Check the liner, clean using pressurized air. Replace the liner if damaged or worn
out.
2. Check the wire pressure setting and adjust if needed.
3. Check the drive rolls for wear and replace if needed.
4. Make sure the filler metal spool can rotate without much resistance.
Adjust the brake hub if needed.