Electrical Connections
Be sure to check the data plate, located on the liner of the cabinet, for required voltage prior to connecting the unit to a power source.
The specifications on the data plate supersede any future discussion.
The standard unit is equipped with a seven (7) foot power cord that requires a properly grounded electrical receptacle. The power
cord comes with a 3 prong plug for grounding purposes. Any attempt to cut off the grounding spike or to connect to an ungrounded
adapter plug will void the warranty, terminate the manufacturers responsibility and could result in serious injury.
The circuit must be protected with a 15 or 20 ampere fuse or breaker. The unit must be isolated on a circuit and not plugged into an
extension cord.

OPERATION

Initial Start Up:
After satisfying the installation requirements, the unit is ready to start. The unit will start when the power cord is connected to the
After satisfying the installation requirements, the refrigerator is ready to start. The Compressor will start when the power cord is
connected to the required power source. If the Compressor does not start when the unit is initially plugged in, check to make sure
that the Temperature Control is not in the "off" position. Allow the unit to run for two hours before loading it with product.
Temperature Control
The Electronic Temperature Control is located on the front of the unit. To check the temperature control set point, push and release
the 'set' button on the control and the display will show the set point temperature. To adjust the set point, push and hold the 'set'
button for two seconds then push the up or down arrows to adjust the set point. Either press the 'set' button again or wait 10 seconds
and the control will store the new set point. Allow the unit a minimum of one hour to respond to a control setting adjustment.
Defrost
Your Silver King refrigerator will defrost naturally and no additional plumbing is required. Evaporator defrosting is accomplished when
frost buildup on the Evaporator Coil is cleared during Compressor "off" cycles. Defrost water is collected in a pan located in the
compressor compartment where it is evaporated into the room air. It is important that the unit be installed level to allow proper
drainage of the defrost water.

MAINTENANCE

Preventative maintenance is minimal although these few steps are very important to continued operation and maximizing the life of
the appliance.
Cabinet Surfaces
The cabinet interior is aluminum and the exterior is stainless steel. These surfaces should be cleaned periodically with a solution of
warm water and mild soap. After cleaning the surfaces should be rinsed with clean water and wiped dry with a soft cloth. Stainless
steel cleaners can be used on the exterior. Should a surface become stained, do not attempt to clean with an abrasive cleaner or
scouring pad. Use a soft cleanser and rub with the grain of the metal to avoid scratching the surface. Always rinse well and dry after
cleaning. Do not use chlorinated cleaners.
Condenser
Periodically, dust on the condenser coil must be cleaned. The condenser is located behind the front cover at the right front of the
unit. Open the front cover by pulling on the left side of the hinged cover, the condenser will be exposed. Clean the accumulated
dust/debris from the condenser with a vacuum or brush or chemical cleaning agent (Nu-Calgon 4171-75 or equivalent). This will
need to be done regularly to maintain the compressor warranty!
Warning – use caution when cleaning the condenser, the fins are very sharp.
Casters
Check to make sure that the casters are installed tightly to the cabinet.