4.OPERATION DETAILS

Remote controller
1
2
3
4
5
6
7
Note: Each mode and relevant function will be further specified in following pages.
Remote Control
The remote controller is not presetting as Cooling Only Air Conditioner or Heat Pump by manufacturer.
Each time after the remote controller replace batteries or is energized, the arrowhead will flashes on the
front of
Heat or
User can preset the remote controller type depending on the air conditioner type you have purchased as
follows:
Press any button when the arrowhead flashes on the front of
Press any button when the arrowhead flashes on the front of
If you don t press any button within 10 seconds, the remote controller is preset as Heat Pump
automatically.
Note :
If the air conditioner you purchased is a Cooling Only one, but you preset the remote controller as Heat
Pump, it doesn t bring any matter. But if the air conditioner you purchased is a Heat Pump one, and you
preset the remote controller as Cooling Only, then you CAN NOT preset the Heating operation with the
remote controller.
TCL Air Conditioner Service Manual
13
12
11
10
9
8
Cool on LCD of the remote controller.
ECO button
1
In cooling mode,press this button ,the temperature
will increase 2
In heating mode, press this button, the temperature
will decrease 2
TEMP DOWN button
2
Decrease the temperature or time by 1 unit.
ON/OFF button
3
To switch the conditioner on and off.
FAN SPEED button
4
To select the fan speed of auto/low/mid/high.
SWING button
5
To activate or deactivate of the movement of the
DEFLECTORS
SLEEP button
6
To activate the function
DISPLAY button
7
To
switch on/off the
HEALTH button
8
To switch - on /off
which controls the ionizer or plasma generator only
for inverter type.
TURBO button
9
In cooling mode, press this button, the unit will give
the maximum cooling temperature with 16
In heating mode, press this button, the unit will give
the maximum heating temperature with 31
SWING button
10
To activate or deactivate of the movement of the
DEFLECTORS
TIMER button
11
To set automatic
9
MODE button
12
To select the mode of operation
TEMP UP button
13
9
crease the temperature or time by 1 unit.
9
Cool
, Cooling Only is set.
Heat , Heat Pump is set.
4
on the base of setting temperature:
on the base of setting temperature.
.---
Side wind
.
SLEEP
LED display (if present)
HEALTHY funtion. It is a button
.---up and down
switching-on/off.
.
.