TCL ERA YA11I Service Manual page 30

Inverter air conditioner
Table of Contents

Advertisement

 Install the indoor unit at a height of at least 2.5m
from the ground.
To install, proceed as follows:
9.2.1 Installation of the mounting plate.
1) By using a level, put the mounting plate in a
perfect square position vertically and horizontally.
2) Drill 32mm deep holes in the wall to fix the plate.
3) Insert the plastic anchors into the hole.
4) Fix the mounting plate by using the provided
tapping screws.
5) Check that the mounting plate is correctly fixed.
Note: The shape of the mounting plate may be
different from the one above, but installation
method is similar.
9.2.2 Drilling a hole in the wall for the piping
1) Decide where to drill the hole in the wall for the
piping (if necessary) according to the position of
the mounting plate
2) Install a flexible flange through the hole in the
wall to keep the latter intact and clean.
The hole must slope downwards towards the
exterior.
Note: Keep the drain pipe down towards the
direction of the wall hole, otherwise leakage may
occur.
9.2.3
Electrical connections---Indoor unit
1).Lift the front panel.
2).Take off the cover as indicated in the picture
(by removing a screw or by breaking the hooks).
3).For the electrical connections, see the circuit
diagram on the right part of the unit under the
front panel.
4).Connect the cable wires to the screw terminals
by following the numbering, Use wire size
suitable to the electric power input (see name
plate on the unit) and according to all current
national safety code requirements.
5).The cable connecting the outdoor and indoor
units must be suitable for outdoor use.
6).The plug must be accessible also after the
appliance has been installed so that it can be
pulled out if necessary.
TCL Air Conditioner Service Manual
27
Indoors
Out doors
5mm
Front panel
Wiring diagram
Terminal block cover

Advertisement

Table of Contents
loading

Table of Contents