Wiring Diagram For Sensor Input; Attaching A Cs-Mount Lens - Sony IPELA SNC-CS50N User Manual

Software version 2.2
Hide thumbs Also See for IPELA SNC-CS50N:
Table of Contents

Advertisement

Wiring diagram for sensor input

Mechanical switch/open collector output
device
Camera
Inside
5 V
2.35
kohms
1 or 3 pin
+
(Sensor In
)
2 or 4 pin (GND)
GND
Wiring diagram for alarm output
Camera
Inside
5 or 7 pin
(Alarm output +)
Magnet relay
24 V AC/24 V
DC, 1 A or less
6 or 8 pin
(Alarm output
92

Attaching a CS-mount Lens

Outside
Mechanical
switch
or
Open collector
output device
Outside
5 V
Circuit
example
)
R
GND
Attaching a CS-mount
Lens
You can use a CS mount lens other than the supplied lens
with this camera.
Suitable lens
The lens must be a CS-mount type of less than 1 kg (2 lb
4 oz). The protrusion behind the mounting surface must
be 4 mm (3/16 in.) or less.
CS-mount lens
4 mm (3/16 in.)
or less
About the auto iris lens
You can use a DC-servo type auto iris lens with this
camera.
To connect the auto iris lens, first replace the plug on the
lens cable with a plug that fits the LENS connector (not
supplied).
1
Detach the old plug from the lens cable.
2
Solder the wires of the lens cable to the pins of the
plug.
For cable pin assignment, refer to the instruction
manual of the lens.
1
8
7
6
5
Cover
1
2
Lens cable
3
Rib (If the cable is thick, cut this off.)
4
Plug (not supplied)
5
Pin 4: Drive – (Ground)
6
Pin 2: Control +
7
Pin 1: Control –
8
Pin 3: Drive +
2
3
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ipela snc-cs50p

Table of Contents