3. Technical specifications

Table 1: Technical data - Indirect Cylinders
Technical parameters in accordance with European Commission regulations 814/2013 and 812/2013
Max No. of elements allowed/fitted
Immersion heat up times at 50° temp. rise
(Btm immersion, 3kW)
Coil surface area (m²)
Coil heat up times
Coil rating (kW) ²
Pressure drop through
coil
Heat loss (kWh/24hrs)
Weight empty (kg)
Weight full (kg) ¹
Volume (Litres) ¹
Mixed water delivery to 40°C
Max mains pressure
Max design pressure
Operating pressure/PRV set pressure
Max primary pressure ³
Expansion relief valve setting
T&P valve setting
T&P Part number
Immersion heater electrical rating
Model(s)
Energy efficiency class
Standing loss W
Storage volume V in Litres
Notes:
1: at 3 bar water inlet pressure the cylinder is filled with the maximum amount of water. Controlled by a 3 Bar P.R.V.
2: at 80°C - +/- 2°C
3: Although the primary coil pressure rating is 1.0MPa (10bar) the 2 port zone valve and coil compression nuts supplied
with the cylinder are only rated at 0.86MPa (8.6 bar). If the cylinder is to be plumbed into a system delivering 1.0MPa (10
bar) a suitable 2 port zone valve and the coil compression nuts will have to be sourced.
4:Tested to EN 12897:2016
3
159
15l/min
30.6
30l/min
26.0
45/min
24.0
15l/min
11.6
30l/min
13.4
45l/min
15.4
15l/min
30l/min
45l/min
1.28
34
170
136
1
176
ErP Data
125i
C
53.3
136
3
3
3
182
212
230
0.51
34.9
40.3
44.8
28.4
34.1
37.0
26.1
30.0
33.1
11.8
12.5
12.8
12.3
12.9
13.2
12.4
13.8
14.4
0.006 MPa (0.06 Bar)
0.022 MPa (0.22 Bar)
0.048 MPa (0.48 Bar)
1.39
1.60
1.82
38
41
41
194
223
238
156
182
197
197
233
258
1.6 MPa (16 Bar)
0.8 MPa (8 Bar)
0.3 MPa (3 Bar)
1.0 MPa (10 Bar)
0.8 MPa (8 Bar)
90°C +/- 5°C/1.0 MPa (10 Bar)
95605209
3.0 kW@240V/2.8kW@230V ~
140i
170i
210i
C
C
C
57.9
66.7
75.8
156
182
197
3
3
276
330
53.3
65.1
43.5
47.9
40.0
47.2
13.0
11.8
15.2
14.3
15.5
15.7
1.84
2.18
51
54
288
337
237
283
320
386
250
300i
C
C
76.7
93.3
237
283
5