SERVICE MANUAL
button.)
Display
set way
Click
the
button, PULL DOWN
mode into 10 seconds
T1
(or open door, lock,
press
the
button, press the "My
zone" button 5 times.)
Click two time TEST
button,
after
seconds into the pre
T2
cooling forced defrost
function (or in the T1,
press
the
button, enter the T2)
Click 5 times TEST
Normal
button,
exit
display
mode
【3】 Exhibition function
Entering mode:
Open the door, locking condition, press the "Freezer" button and press
"Lock" button 5 times to enter the exhibition function.
Exit mode:
The exhibition function, open the door, locking condition, press the "Freezer"
button and press "Lock" button 5 times to exit the exhibition function.
Control mode :
The refrigerator enter into the exhibition function mode,PC, frozen lights,
blue lights , compressor, fan, air switch, heating wire and other load stop working, the
refrigerator display can work
control way
1) COMP high speed
64Hz;
2) F-FAN 12V;
TEST
3) DEF-HTR OFF;
4) Refrigerated door
fully open;
5) The variable
"Fridge"
temperature damper
opens the angle for
30°;
6) Display panel
displayT1。
1) COMP OFF;
2) F-FAN OFF;
3) DEF-HTR ON;
4)PC air switch off;
10
5)my zone air switch
off;
6)Panel display T2;
7)
"Lock"
Cancel the defrost in
defrosting
immediately
defrost
Restore normal
control
TEST
This function does not quit without
manual withdrawal or power failure.
Start to frost:
If D-SNR = 12 degree, D-HTR 10S exit;
If D-SNR is less than 12 degree, then
D-HTR to D-SNR reached 12 degrees (the
longest 90min D-SNR exit forced exit;
D-SNR fault, the 30min exit) exit;
process,
Manual forced exit, exit
quit
/
Remark