Siemens RUGGEDCOM RSG909R Installation Manual page 52

Hide thumbs Also See for RUGGEDCOM RSG909R:
Table of Contents

Advertisement

Chapter 6
Certification
Environmental Type Tests
Test
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
IEC 60068-2-14
IEC 60068-2-78
IEC 60255-21-1
IEC 60255-21-2
IEC 60255-21-2
IEC 60255-21-3
IEC 60529
42
Description
Cold Temperature
Cold Storage
Dry Heat
Dry Heat Storage
Humidity (Damp
Heat, Cyclic)
Change of Temperature
Humidity (Damp
Heat, Cyclic)
Vibration
Shock
Bump
Seismic
Ingress Protection
Test Levels
Test Ad
-40 °C (-40 °F), 16 Hours
Test Ab
-40 °C (-40 °F), 16 Hours
Test Bd
85 °C (185 °F), 16 Hours
Test Bd
85 °C (185 °F), 16 Hours
Test Dd
95% (Non-Condensing),
55 °C (131 °F), 6 Cycles
Test Nb
5 Cycles @ -40 to 85
°C (-40 to 185 °F)
Test Cab
10 Days @ 55 °C
(131 °F), 6 Cycles
2 g @ 10 to 150 Hz
30 g @ 11 ms
10 g @ 16 ms
Method A
RUGGEDCOM RSG909R
Installation Guide
Severity Levels
Class 2
Class 2
Class 1
Class 2
IP4x
EMC and Environmental Type Tests