Benchmark UNICA HE Series Installation & Servicing Instructions Manual page 14

Table of Contents

Advertisement

"X"
"X"
28/32/36 HE = 218 mm
12/15/20HE = 202mm
25/30/35HE = 218mm
Fig. 11
Fit the appropriate flashing plate to the roof and
insert the vertical flue terminal through the flashing
plate from the outside, ensuring that the collar on
the flue terminal fits over the flashing.
The fixing holes for the wall-mounting bracket/
fixing jig should now be drilled and plugged, an
appropriate type and quantity of fixing should be
used to ensure that the bracket is mounted
securely. Once the bracket has been secured to
the wall, mount the appliance onto the bracket.
IMPORTANT
The vertical flue terminal is 1.0 metre in length and
cannot be cut; therefore it may be necessary to
adjust the height of the appliance to suit or use a
suitable extension.
Connect the vertical flue assembly to the boiler
flue spigot using the 100mm clip, gasket, &
screws (supplied), ensuring the correct seal is
made. The flue support bracket (supplied with the
vertical flue kit) can now be fitted.
If the vertical flue requires extension/s or additional
bend/s, connect the required number of flue
extensions or bends (up to the maximum equivalent
flue length) between the boiler and vertical flue
assembly (see fig. 10).
Ensure that any horizontal sections of the flue
system have a minimum 1º; maximum 3º fall back
to the boiler (1º = 17mm per 1000mm)
NOTE
When cutting an extension to the required length,
you must ensure that the excess is cut from the
plain end of the extension (see fig. 8). Remove
any burrs, and check that any seals are located
properly.
You must ensure that the entire flue system is
properly supported and connected.
12
4.5.3
TWIN FLUE SYSTEM
The Vokera twin flue system enables greater flue
distances to be achieved (see 4.4.2) than that of
a concentric flue system.
horizontal or vertical applications, however the
twin flue system must be converted to the dedicated
concentric flue kit for termination. It is essential
that the installation of the twin flue system be
carried out in strict accordance with these
instructions.
GUIDANCE
NOTES
INSTALLATION
• The flue must have a have a minimum 1º;
maximum 3º (1º = 17mm per 1000mm) fall back
to the appliance to allow any condensate that
may form in the flue system to drain via the
condensate drain. Consideration must also be
given to the fact that there is the possibility of a
small amount of condensate dripping from the
terminal.
• Ensure that the entire flue system is adequately
supported, use at least one bracket for each
extension.
• The entire flue system must be adequately
insulated to maintain heat within the flue system
thereby reducing the possibility of condensate
production.
• As the exhaust outlet pipe can reach very high
temperatures it must be protected to prevent
persons touching the hot surface.
• The condensate drain pipe must be connected in
accordance with building regulations
Reduction for bends
Bend
Reduction in maximum flue length for
each bend
45º bend
1.0 metre
90º bend
1.0 metre
Twin flue accessories
Part No.
Description
0225805
Horizontal flue terminal
0225810
Vertical flue terminal
359
Twin adapter kit
531
Pitched roof flashing plate
532
Flat roof flashing plate
0225815
Condensate drain kit
0225820
0.25m extension (pair)
0225825
0.5m extension (pair)
0225830
1.0m extension (pair)
0225835
2.0m extension (pair)
0225840
45º bend (pair)
0225845
90º bend (pair)
0225850
Twin bracket (5)
0225855
Single bracket (5)
MOUNTING THE BOILER
The fixing holes for the wall-mounting bracket
should now be drilled and plugged, an appropriate
type and quantity of fixing should be used to
ensure that the bracket is mounted securely.
Once the bracket has been secured to the wall,
mount the appliance onto the bracket.
4.5.3.1 INSTALLATION OF TWIN ADAPTOR KIT (fig. 12
& 13)
• Insert the exhaust connection manifold (A) onto
the appliance flue outlet.
• Remove the blanking plate (located to the right
of the appliance flue outlet) and – using the same
It can be used for
ON
TWIN
FLUE
Length
1.0 metre
1.0 metre
N/A
N/A
N/A
N/A
250mm
500mm
1000mm
2000mm
N/A
N/A
N/A
N/A