Advertisement

Quick Links

MatriX 1050-serie
40011616-1714 MatriX 1050 ENG

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MatriX 1050 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Faber MatriX 1050 Series

  • Page 1 MatriX 1050-serie 40011616-1714 MatriX 1050 ENG...
  • Page 2 I n s t a l l a t i o n I n s t r u c t i o n s...
  • Page 3 I n s t a l l a t i o n I n s t r u c t i o n s...
  • Page 4 I n s t a l l a t i o n I n s t r u c t i o n s...
  • Page 5 I n s t a l l a t i o n I n s t r u c t i o n s...
  • Page 6 I n s t a l l a t i o n I n s t r u c t i o n s...
  • Page 7 I n s t a l l a t i o n I n s t r u c t i o n s...
  • Page 8 I n s t a l l a t i o n I n s t r u c t i o n s...
  • Page 9 I n s t a l l a t i o n I n s t r u c t i o n s...
  • Page 10 I n s t a l l a t i o n I n s t r u c t i o n s...
  • Page 11 I n s t a l l a t i o n I n s t r u c t i o n s...
  • Page 12 I n s t a l l a t i o n I n s t r u c t i o n s...
  • Page 13: Installation Requirements

    For devices with flexible gas pipes, the gas regulator block is mounted on the right side of the fire for transport reason (fig Glen Dimplex Benelux certifies that this Faber fire complies with the 1.6). The gas regulator block with the receiver and the I.T.C.
  • Page 14: Preparation And Installation Instructions

    Ø100mm or Ø130mm with CE marking opto-couples are recommended! for 600°C. 4.2.2 Faber ITC (Intelligent Technical Controller) > Please note: The minimum chimney diameter for a 130mm flexible stainless The ITC gives you more options, such as ECO control, control, steel pipe must 200x200mm.
  • Page 15: Removing The Glass

    I n s t a l l a t i o n I n s t r u c t i o n s 4.4.1 Hanging on the wall (1050/650-IIL,-IIR and 4.6.3 Method I with cover strip (fig. 2.2) 1050/650-III) Build the false chimney breast or plateau against the moldings H The appliance can be wall-mounted with the optional wall bracket and distance profiles I (see fig.
  • Page 16: Checking The Installation

    I n s t a l l a t i o n I n s t r u c t i o n s Removing the glass from the side Checking the burner pressure and primary pressure It is not necessary to take out the glass from the side to place the log set or for maintenance.
  • Page 17: Annual Maintenance

    A simple way to calculate whether the exhaust configuration is is not allowed. Only then adjust the TVH or THL. possible in combination with your fire, use the free “Faber Flue App” If a value is indicated, check that the calculated STL value is not lower than indicated in the table.
  • Page 18 I n s t a l l a t i o n I n s t r u c t i o n s 11.1 Restrictor table (100/150) NG MatriX 1050/500 and 1050/650 Starting length (STL), Vertical (TVH) and Horizontal (THL) 40,2 45,2 45,2...
  • Page 19 I n s t a l l a t i o n I n s t r u c t i o n s 11.2 Restrictor table (130/200) NG MatriX 1050/500 Starting length (STL), Vertical (TVH) and Horizontal (THL) 30,4 30,4 30,4 30,3...
  • Page 20 I n s t a l l a t i o n I n s t r u c t i o n s 11.3 Restrictor table (130/200) NG MatriX 1050/650 Starting length (STL), Vertical (TVH) and Horizontal (THL) 30,4 30,3 30,4 30,4...
  • Page 21 I n s t a l l a t i o n I n s t r u c t i o n s 11.4 Restrictor table (130/200) LPG MatriX 1050/500 Starting length (STL), Vertical (TVH) and Horizontal (THL) 40,4 30,4 30,4 40,4...
  • Page 22 I n s t a l l a t i o n I n s t r u c t i o n s 11.5 Restrictor table (130/200) LPG MatriX 1050/650 Starting length (STL), Vertical (TVH) and Horizontal (THL) 40,4 40,4 40,4 30,4...
  • Page 23 I n s t a l l a t i o n I n s t r u c t i o n s Examples flue materials fig. 12.1 fig.12.2 fig. 12.3...
  • Page 24 I n s t a l l a t i o n I n s t r u c t i o n s Calculation sheet Starter length (STL) First part on top of the appliance Value Flue length from 0,1m till 0,45m Flue length from 0,5m till 0,90m Flue length from 1m till 1,4m Flue length from 1,5m till 2m...
  • Page 25 I n s t a l l a t i o n I n s t r u c t i o n s found value Search in the table at TVH and THL and enter the value that is found. ………………………………...
  • Page 26: Tecnical Data

    I n s t a l l a t i o n I n s t r u c t i o n s Tecnical data 14.1 MatriX 1050/500 II2H3+ II2H3+ II2H3+ Gas category Type appliance C11/C31/C91 C11/C31/C91 C11/C31/C91 Reference gas Input Hi Efficiency class NOx-class...
  • Page 27 I n s t a l l a t i o n I n s t r u c t i o n s 14.2 MatriX 1050/650 II2H3+ II2H3+ II2H3+ Gas category Type appliance C11/C31/C91 C11/C31/C91 C11/C31/C91 Reference gas Input Hi 11,3 11,3 11,3...
  • Page 28: Terminal Position

    I n s t a l l a t i o n I n s t r u c t i o n s Terminal position > Please note: These rules apply only for the proper functioning of the unit, for ventilation and environmental protection you need to comply with the applicable rules Short roof terminal.
  • Page 29: Troubleshooting Guide

    I n s t a l l a t i o n I n s t r u c t i o n s Troubleshooting guide - See inst. manual. - Learn a new code for remote. Light the pilot flame with - 1x 9V Alkaline.
  • Page 30 I n s t a l l a t i o n I n s t r u c t i o n s - Check the complete - Short circuit in the Pilot stays lit wiring of thermocouple thermocouple circuit. circuit.
  • Page 31 I n s t a l l a t i o n I n s t r u c t i o n s - RESET the receiver Optional: - Repaire the wiring. - Check the wiring from Step burner function can solenoid valve to receiver.
  • Page 32: Dimensional Drawings

    I n s t a l l a t i o n I n s t r u c t i o n s Dimensional drawings 17.1 MatriX 1050/500-I...
  • Page 33 I n s t a l l a t i o n I n s t r u c t i o n s 17.2 MatriX 1050/500-IIL...
  • Page 34 I n s t a l l a t i o n I n s t r u c t i o n s 17.3 MatriX 1050/500-IIR...
  • Page 35 I n s t a l l a t i o n I n s t r u c t i o n s 17.4 MatriX 1050/500-III...
  • Page 36 I n s t a l l a t i o n I n s t r u c t i o n s 17.5 MatriX 1050/650-I...
  • Page 37 I n s t a l l a t i o n I n s t r u c t i o n s 17.6 MatriX 1050/650-IIL...
  • Page 38 I n s t a l l a t i o n I n s t r u c t i o n s 17.7 MatriX 1050/650-IIR...
  • Page 39 I n s t a l l a t i o n I n s t r u c t i o n s 17.8 MatriX 1050/650-III...
  • Page 40 I n s t a l l a t i o n I n s t r u c t i o n s 17.9 Wall bracket 1050/500...
  • Page 41 I n s t a l l a t i o n I n s t r u c t i o n s 17.9 Wall bracket 1050/650...
  • Page 42 I n s t a l l a t i o n I n s t r u c t i o n s 17.10 Remote acces door...
  • Page 43 I n s t a l l a t i o n I n s t r u c t i o n s 17.11 Ventilation grid...
  • Page 44 I n s t a l l a t i o n I n s t r u c t i o n s 17.12 Adjustable feet...
  • Page 45 I n s t a l l a t i o n I n s t r u c t i o n s...
  • Page 46 I n s t a l l a t i o n I n s t r u c t i o n s...
  • Page 47 I n s t a l l a t i o n I n s t r u c t i o n s...
  • Page 48 I n s t a l l a t i o n I n s t r u c t i o n s Dealerinfo: www.faber.nl info@faber.nl Saturnus 8 NL - 8448 CC Heerenveen Postbus 219 NL - 8440 AE Heerenveen...

Table of Contents