Mounting; Quick Installation Guide - Endress+Hauser Levelflex M FMP40 Operating Instructions Manual

Guided level-radar
Hide thumbs Also See for Levelflex M FMP40:
Table of Contents

Advertisement

Levelflex M FMP40 FOUNDATION Fieldbus
Endress+Hauser
3

Mounting

3.1

Quick installation guide

Mounting with threaded boss
F12/F23 or T12 housing
Turn housing
To simplify access to the
display and the terminal compartment
1.
When using an aramid fibre seal and a process pressure of 40 bar: 140 Nm
Maximum permissible torque: 450 Nm
2.
When using an aramid fibre seal and a process pressure of 40 bar: 25 Nm
Maximum permissible torque: 45 Nm
AF 60
1.
1½"
2.
¾"
AF 50
F12/F23 or T12 housing
2
3
Allen key
4 mm / 0.1"
1
Mounting
Caution!
Use only the
threaded boss
L00-FMP4xxxx-17-00-00-en-029
11

Advertisement

Table of Contents
loading

Table of Contents