The position of each fan of the fixture:
BaseFan1
BaseFan2

9.Troubleshooting

Following are a few common problems that may occur during operation. Here are some
suggestions for troubleshooting:
A. The unit does not work, no light and the fan does not work
- Check the connected power.
- Measure the voltage.
- Check the power indicator to see whether it can be lit up or not.
B. Not responding to the DMX controller
- Check whether the DMX connectors and the DMX cables are connected correctly.
- Check whether the DMX address is correctly set.
- If the intermittent DMX signal problem occurs, check whether the XLR socket and the signal cable
are well connected.
- Try it with another DMX controller.
- Check whether the DMX cables run near or alongside to the high-voltage cables, which may
damage or interfere with the signal circuit.
C. One of the channels is not working well
- The stepper motor might be damaged or the cable connected to the PCB might be broken.
- The motor's drive IC on the PCB might be out of condition.