12. Gobo1:
Check whether there are other objects in the revolution and operation range of Gobo1 interfering with
its operation and reset.
Check whether the connection line of the connection Gobo1 male wheel magnetic induction board is
in poor contact or disconnected.
Check if the revolving magnet of Gobo1 is loose, fallen off or damaged.
Check the Gobo1 revolution magnetic induction plate for looseness, falling off or damage.
Check if the circuit related to the Gobo1 revolution motor driver board is damaged.
Check if the Gobo1 revolution motor is damaged.
13. Gobo1 Rot.:
Check whether there are other objects in the revolution and operation range of Gobo1 Rot. interfering
with its operation and reset.
Check whether the connection line of the connection Gobo1 Rot. male wheel magnetic induction
board is in poor contact or disconnected.
Check if the revolving magnet of Gobo1 Rot. is loose, fallen off or damaged.
Check the Gobo1 Rot. revolution magnetic induction plate for looseness, falling off or damage.
Check if the circuit related to the Gobo1 Rot. revolution motor driver board is damaged.
Check if the Gobo1 Rot. revolution motor is damaged.
14. Gobo2:
Check whether there are other objects in the revolution and operation range of Gobo2 interfering with
its operation and reset.
Check whether the connection line of the connection Gobo2 male wheel magnetic induction board is
in poor contact or disconnected.
Check if the revolving magnet of Gobo2 is loose, fallen off or damaged.
Check the Gobo2 revolution magnetic induction plate for looseness, falling off or damage.
Check if the circuit related to the Gobo2 revolution motor driver board is damaged.
Check if the Gobo2 revolution motor is damaged.