TROUBLESHOOTING.

PROBLEM
The wet/dry vacuum will
not operate.
The dust comes out from
the motor cover.
Reduced efficiency and
motor/speed vibration.
Page 21
TROUBLESHOOTING
TO REDUCE THE RISK OF ELECTRIC SHOCK, UNPLUG BEFORE
POSSIBLE CAUSE
1) No power supply.
2) Faulty power cord.
3) Collection tank is full.
4) Switch in the wrong position.
1) The cartridge filter is missing
or damaged.
2) Vacuum has been used to
collect fine dust, such as dry
wall dust, fireplace soot, or
ash, without a fine dust filter
equipped.
1) There are blockages in
the nozzle or hose, or the
collection tank inlet.
2) The cartridge filter is clogged
by fine dust.
SOLUTION
1) Check the power supply, cord,
breakers, and fuses.
2) Unplug and check the power cord.
If damaged, have it repaired by a
professional.
3) Empty the collection tank.
4) Press the ON 'I' button on the
power head.
1) Attach or replace cartridge filter.
2) Remove the standard cartridge
filter and install the appropriate
fine dust filter.
1) Unplug and check nozzle, hose,
and collection tank inlets for
blockages.
2) Take off the filter and clean it or
install a new cartridge filter.