Wiring Diagram - Transmitter Solutions Dolphin DOLCWIUHF-ER-902 Manual

Uhf reader
Table of Contents

Advertisement

INSTALLATION MANUAL
DOLCWIUHF-ER-902
UHF READER
8

Wiring Diagram

110 - 230 Vac
RF Reader 2
(1)
(1)
White
Green
Black
Red
T T rigger
rigger
RF Reader 1
(1)
(1)
White
Green
Black
Red
T T rigger
rigger
Trigger signal
Floating / connected to GND
Connected to Vdc
FFF = FACILITY CODE
NNN = SERIAL NUMBER
Example 1: TX reception
F F F N N N N N
R 1 a b c d R 2
Button activated
Relay activated
a, b, c or d
Ref
Description
Cable from reader
(1)
( 0,7m )
(2)
Wiegand BUS
(3)
Power supply
4
Buzzer
RED
RED
+ + 12dc
12dc
BLACK
BLACK
GND
GND
RECEIVER
A A
P1 P2 P3 P4
B B
A
A
B B
L1
L1
Reader operating mode
Reading
Disabled (*)
Example 2 : Status of the relays
TX Serial
R 1
number
P U L S E
Relay 1 : Pulse
R 2
0 0 : 0 1 : 0 5
Relay 2 : Timed
Wire type
2 conductors ( RS485 bus)
2 conductors ( Power supply)
3 conductors Belden 9553
2 conductors
Connector for
backup memory
UHF
Backlit
LCD Display
Pull-UP W Wiegand
Pull-UP
J2 ON = 9V
J2 ON = 9V
J2 OFF = 5V
J2 OFF = 5V
RG58
RG58
(3)
(3)
BLACK GND
BLACK GND
RED +12dc
RED +12dc
Power supply ( included ).
NOTE: for indoor installations only.
(*) : use an external device with a dry contact to enable/disable the
(*) : use an external device with a dry contact to enable/disable the
detection of the reader
detection of the reader
R 1
S T E P
Relay 1 : Step
R 2
D I S A B L E D
Relay 2 : Disabled
Optional extension size
24AWG ( 0,51 mm
)
2
18AWG ( 1,02 mm
)
2
22AWG ( 0,64 mm
) to 18AWG ( 1,02 mm
2
18AWG ( 1,02 mm
)
2
P1, P2 :
navigate
the menu
P4 : back to
upper level
iegand
P3 : enter the menu
( 4 sec.)
or
confirm the choice
SEA433
SEA433
(2)
(2)
D1
D1
Wiegand Out
D0
D0
GND
GND
110 - 230 Vac
3
Delay setting
h h
m m
s s
0 0 : 0 0 : 0 1
The factory value for the timing is 1
sec. Use P1 to scroll the digits and P2
to confirm
Maximum length
4000 ft
L1 = 100 ft MAX
)
490 ft
2
L1 = 100 ft MAX
EN
Fig. 7

Advertisement

Table of Contents
loading