INSTALLATION MANUAL
AHU49
UHF READER
Example 3 : Double reader and double interface configuration
In case of more interfaces connected to an Access Control Panel, it is necessary to assign each a different address , which will
be sent on the bus wiegand ( see par.25). This is done by setting the parameter "Code" on the menu Settings to each device. The
factory wiegand address is 1.
(*) : Despite having a different wiegand address, it is advisable to use different input ports on the access control to avoid overlaps
caused by simultaneous activations.
21
Settings
m e n u
S e t t i n g s
NOTE: the manual assignment of the parameters for Address1 and Address2 is necessary in case of replacement of
10
the antenna as the automatic assignment takes place only if the parameter is 000, factory setting.
250
RS-485
1
251
I n t e r v a l
S e t t i n g s
I n t e r v a l
1 0
S e t t i n g s
D e a d T i m e
D e a d T i m e
5
S e t t i n g s
A n t e n n a 1
A n t e n n a
A d d r e s s
A n t e n n a 1
A n t e n n a 1
P o w e r
A n t e n n a 1
00051
RS-485
2
00099
Wiegand (*)
Wiegand
Sets the interval time between 2 next trains of bits
carrying the S/N of the tag detected by the reader,
as long as the tag stands in the field generated by
the UHF reader.
Values available : [0, 5, 10, 20, 30 Sec.]
Set the "deadtime" that is the time in which a tag,
once carried out, must remain outside the detec-
tion field to be detected again.
Avaliable values [0, 1, 2, 3, 4, 5, 6, 7, 8 , 9 Sec.]
A d d r e s s 1
W i e g a n d 1
C o d e
P o w e r
B u z z e r
B u z z e r
O N
Access
control
panel
W2
W1
Set the address of the reader [1 - 254]
on RS-485. See the sticker on the
0 0 1
reader or make the reading of a card
Set the address of the interface [1 - 9]
on bus Wiegand ( see par. 25)
1
Set the transmitting power of the
1
reader. Power settings control the
3 0
detection range of the UHF reader. See
table at left of this page. (Detection
range may be affected by obstacles in
the detection area)
1
Enable/disable the buzzer of the
reader while detecting the tag
EN