40 | Menu settings INSTALLER SETTINGS (contractors only)
8.1.2 INSTALLER SETTINGS: Heating parameters
Menu structure
Heating parameters
Heating circuit type
Foot point
End point
Design flow temp.
Maximum CH flow temperature
Room influence
Room influence enabled for
levels
Sensor(s) used for room
influence
Room temperature offset
Heating off until lower level
reached
Heating off at outside
temperature
Freezing risk at outside
temperature
Calibrate room temp sensor on
FB10
Mixer running time
Minimum outside temperature
Building storage capacity
Calibrate internal room temp
sensor
8.1.3 INSTALLER SETTINGS: Solar system config
Menu structure
Solar system config
Solar sys option E Thermal
disinfection
6 720 800 844 (2012/02)
Factory
setting
Setting range
Radiators
Foot point/End point | Underfloor
heating | Radiators | Convectors
25 °C
10 °C ... 85 °C
75 °C
30 °C ... 85 °C
75 °C
30 °C ... 85 °C
80 °C
30 °C ... 85 °C
30 %
0 % ... 100 %
Eco/Frost
Eco/Frost | Comfort/Eco/Frost
Lower
Sensor on FB10 | Internal sensor |
temperature
Lower temperature
(only with FB 10)
0.0 K
– 5.0 K ... 5.0 K
Yes
No | Yes
20.0 °C
10.0 °C ... 25.0 °C, 99.0 °C
(= function off)
3.0 °C
– 5.0 °C ... 10.0 °C
0.0 K
– 3.0 K ... 3.0 K (only with FB 10)
140 s
10 s ... 600 s
– 15 °C
– 30 °C ... 0 °C
50 %
0 % ... 100 %
0.0 K
– 3.0 K ... 3.0 K
Factory
setting
Setting range
No
No | Yes
Personal
Description
setting
from page
43
°C
45
°C
45
°C
45
°C
45
%
45
45
46
K
46
46
°C
46
°C
46
K
47
s
47
°C
47
%
47
K
47
Personal
Description
setting
from page
49