Prepare A Dm7100F Or Dg7000 Ha Pair To Hot-Add A Second Shelf - Lenovo DM240N Manual

Hot-add a shelf, shelves, support for dg5000 and dg7000
Hide thumbs Also See for DM240N:
Table of Contents

Advertisement

Otherwise, go to the next step.
The reboot can take up to 15 minutes.
5. Repeat steps for the second controller module:
If your HA pair is
running...
ONTAP 9.7 or later
ONTAP 9.6
6. Verify that the non-dedicated ports on both controller modules are configured for storage use:
storage port show
You can enter the command on either controller module.
If your HA pair is running ONTAP 9.8 or later, the non-dedicated ports display
Mode
column.
If your HA pair is running ONTAP 9.7 or 9.6, the non-dedicated ports, which display
Is Dedicated?
column, also display

1.3.2. Prepare a DM7100F or DG7000 HA pair to hot-add a second shelf

If you have a DM7100F or DG7000 HA pair with one DM240N drive shelf that is cabled to one set of
RoCE-capable ports on each controller, you must recable the shelf (after you have installed the
additional RoCE-capable PCIe cards or I/O modules) across both sets of ports on each controller,
before hot-adding the second shelf.
Before you begin
• You must have met the system requirements.
Requirements for a hot-add
• You must have enabled the ports on the RoCE-capable PCIe cards or I/O modules you
installed.
Prepare non-dedicated RoCE-capable ports for a hot-add
4
Then...
a. Repeat step 3.
b. Go to step 6.
a. Repeat steps 3 and 4.
The first controller must have already completed
its reboot.
b. Go to step 6.
enabled
in the
State
column.
storage
in the
false
in the