Summary of Contents for Defro Home MYPELL

  • Page 1 □...
  • Page 2 This Declaration of Conformity becomes invalid if any changes have been made to the DEFRO HOME MYPELL Dry Stove, if its construction has been changed without our permission or if the dry stove is used not in accordance with the operating manual. This Declaration shall be handed over to a new owner along with the title of ownership of the dry stove.
  • Page 3 Dear Customer, Dear Customer, We would like to thank you for choosing the high-quality DEFRO prod- We would like to inform you that we make every effort to offer the uct which will ensure your safety and operational reliability. products of quality fulfilling the most restrictive standards and warrant- As our customers, you can always count on the help of the DEFRO ing operational safety.
  • Page 4: Table Of Contents

    Air intake from the room ..................................9 5.3.2. Air intake from outside ..................................10 5.4. Forced system for hot air distribution in DEFRO HOME MYPELL DGP ....................10 5.5. Installation to the flue ....................................10 5.6. Connection to electrical wiring system ..............................11 USAGE AND OPERATION ....................................
  • Page 5: Information

    1. INFORMATION 2. BASIC SAFETY RULES The operating manual is an integral and essential part of the prod- 2.1. SAFETY WARNINGS uct and must be forwarded to the user also in the case when the prop- • The national and local provisions should be met. erty is transmitted.
  • Page 6: Warnings Related To Operation

    Minimum distances are given in point 5.2 3. INTENDED USE of the operating manual. The DEFRO HOME MYPELL dry stoves are intended for the com- • It is absolutely forbidden to use flammable liquid for bustion of pellet. They are intended for heating of houses and spaces equipment firing up.
  • Page 7: Technical Data

    Picture 3. Dimensions of the DEFRO HOME MYPELL heating stove. supply socket, 20 – temperature sensor socket. 4.2. TECHNICAL DATA Table 1. Technical data of the DEFRO HOME MYPELL I DEFRO The combustion process in a stove fired with pellet is adjusted by HOME MYPELL DGP heating stove.
  • Page 8: Equipment

    Sawdust granulate, called pellet, is a primary fuel for the DEFRO will minimize the possibility of damage to the device housing. MYPELL heating stove. It is recommended to use A1 class pellet in All remaining parts of the packing should be removed in such a accordance with PN-EN ISO 17225-2:2014-07, with the following pa- way that it will not pose any hazard for people and animals.
  • Page 9: Working Environment

    5.3. AIR INTAKE Distance from The DEFRO HOME MYPELL stove intakes the air through the con- combustible ma- nector (air intake) located at the rear of the equipment. Air for combus- terial tion may be taken: •...
  • Page 10: Air Intake From Outside

    (air intake) pipe, which can be also used outdoors, to avoid the occurrence of con- densate. The correctly executed connector between the DEFRO HOME MYPELL stove and the flue or smoke duct should meet the following Króciec wlotu powietrza (czerpnia) conditions: •...
  • Page 11: Connection To Electrical Wiring System

    Flue gas discharge system from DEFRO HOME MYPELL stove should be tighter than in the case of typ- Tee pipe with ical systems in stoves without active flue gas removal. droplet elimina- Lack of proper tightness will result in penetration of flue gases to the room where the stove is located.
  • Page 12: First Start-Up And Operation

    The stove is subject to expansion and shrinkage during warming More information concerning servicing the controller is included in and cooling down stage what may cause slight squeaks. This is an ab- the NG01 AIR controller’s operating manual. solutely normal phenomenon because the structure of the equipment Housing components will be very hot during operation.
  • Page 13: Every Day Service

    Remove ash-pan for this purpose and remove the remaining dust. Dust Lift the burner. can be removed using a vacuum cleaner only if it is completely cold. Use a vacuum cleaner adapted to remove the particles of specified size for this purpose. Remove the burner to the outside.
  • Page 14: Every Year Service

    Remove the screws fixing the plate supporting the bottom deflec- Clean the available space behind the ash-pan using the vacuum tor. cleaner. 7.1.5. EVERY YEAR SERVICE Once a year it is recommended to disassemble side plates made of vermiculite from the combustion chamber and to clean smoke ducts locates behind them.
  • Page 15: Window Panel Cleaning

    It is forbidden to use abrasive agents or materials, be- cause they may scratch the glass surface. It is forbidden to use the chemical cleaning agents, be- cause, in the case of contact with such agents they may cause damage to the components of the fireplace in- sert, that is printed on the glass pane, glass pane, gas- kets, and painted surfaces.
  • Page 16: Dismantling Of Components

    7.3. DISMANTLING OF COMPONENTS 7.3.1. DOORS DISASSEMBLY Remove the upper and bottom side strip and remove the window panel. 7.4. SHUTTING THE STOVE DOWN Open the doors and lift them fully upwards position to remove bottom pin of the hinge from a sleeve. It is recommended completely shutdown the stove and clean the equipment when each heating season is finished.
  • Page 17: Removal Due To Wear-Out

    sweeps. In a case of soot fire in a chimney the following recommenda- 12) For connection to the external inlet of air and longer break in op- tions should be observed: eration (over 2 weeks) it is necessary to empty the bin and pellet •...
  • Page 18: Warranty Conditions "48H Service

    30 days after the fault report, if the repair requires replace- Faults are not significant and do not have an impact on the ment of constructions elements of the product; use value of the product. subject to points 3 and 4 of these warranty conditions. 18) This warranty does not cover: If, as a result of considering the warranty claim the defective prod- products used for business purposes or industrial uses;...
  • Page 19 The "48h service" ensures that DEFRO R. Dziubeła sp. k. does its best to remove any faults which make it impossible/difficult for the equipment to operate within the period of two business days from the day of fault registration. Fault removal time may be prolonged for reasons not dependent on DEFRO R.
  • Page 20 20 | Page...
  • Page 21: Warranty Card

    WARRANTY CARD Confirmation of equipment's quality and completeness In accordance with the conditions stated herein, warranty for a heating stove of DEFRO HOME MYPELL series type ....... operated in compliance with the operating manual has been issued. Equipment manufacturing number* ......................
  • Page 22: Carried Out Warranty Repairs And Maintenance

    14. CARRIED OUT WARRANTY REPAIRS AND MAINTENANCE. fault description, repaired element, Stamp and signature date comments description of repairs of Service 22 | Page...
  • Page 23: Warranty Card (Copy To Send Back)

    WARRANTY CARD Confirmation of equipment's quality and completeness In accordance with the conditions stated herein, warranty for a heating stove of DEFRO HOME MYPELL series type ....... operated in compliance with the operating manual has been issued. Equipment manufacturing number* ......................
  • Page 24 24 | Page...
  • Page 25: Complaint Form

    16. COMPLAINT FORM COMPLAINT FORM made on ........... in connection with complaint no......SUBJECT OF COMPLAINT EQUIPMENT TYPE: ..........Equipment manufacturing date: ..........Equipment serial no.: ..........Equipment purchase date: ..........CLAIMANT Name and surname: ................................... Detailed address: ..................................................................
  • Page 26 26 | Page...
  • Page 27: Complaint Form

    17. COMPLAINT FORM COMPLAINT FORM made on ........... in connection with complaint no... SUBJECT OF COMPLAINT EQUIPMENT TYPE: ..........Equipment manufacturing date: ..........Equipment serial no.: ..........Equipment purchase date: ..........CLAIMANT Name and surname: ................................... Detailed address: ..................................................................
  • Page 28 28 | Page...
  • Page 29: Complaint Form

    18. COMPLAINT FORM COMPLAINT FORM made on ........... in connection with complaint no......SUBJECT OF COMPLAINT EQUIPMENT TYPE: ..........Equipment manufacturing date: ..........Equipment serial no.: ..........Equipment purchase date: ..........CLAIMANT Name and surname: ................................... Detailed address: ..................................................................
  • Page 30: Register Of Inspections Of Smoke Duct

    19. REGISTER OF INSPECTIONS OF SMOKE DUCT date stamp and signature of chimneysweep date stamp and signature of chimneysweep 30 | Page...
  • Page 31 31 | Page...
  • Page 32 32 | Page...
  • Page 33 PRODUCT SHEET in accordance with the Commission Regulation 2015/1185 on the execution of the Directive of the European Parliament and the Council 2009/125/EC Equipment parameters Model identifier(s): DEFRO HOME MYPELL 9 Indirect heating function: [yes/no] Direct thermal output: (kW) Indirect thermal output: N/A (kW)
  • Page 34 Properties in the case of operation only with recommended fuel Parameter Designa- Value Unit Parameter Designa- Value Unit tion tion Thermal output Performance (calorific value in operating condition) Rated heat out- Performance at 90.9 η th,nom rated thermal power Minimum heat Performance at η...