Page 1
DEFRO HOME SLIMPELL translation of the original operating manual issue 5 June 2020...
Page 2
DEKLARACJA ZGODNOŚCI WE DECLARATION OF CONFORMITY EC nr 71/A‐4/01/2017 DEFRO Spółka z ograniczoną odpowiedzialnością Spółka komandytowa 00‐403 Warszawa, ul. Solec 24/253 Manufacturing plant: 26‐067 Strawczyn, Ruda Strawczyńska 103A DEKLARUJE / DECLARES z pełną odpowiedzialnością, że produkt / with all responsibility, that the product Piec kominkowy na pellet/ Dry Stove for Pellets DEFRO HOME SLIMPELL 9 kW (typ/type DEFRO HOME SLIMPELL) zaprojektowany, wyprodukowany i wprowadzony na rynek zgodnie z następującymi dyrektywami: has been designed, manufactured and placed on the market in conformity with directives: został Rozporządzenie Parlamentu Europejskiego / Regulation of the European Parliament 305/2011 Rozporządzenie Komisji (UE) / Commission Regulation (EU) 2015/1185 i niżej wymienionymi normami zharmonizowanymi: and that the following relevant Standards: PN‐EN 14785:2009 dokumentacja techniczna / technical documentation Wyrób oznaczono znakiem: Product has been marked: Ta deklaracja zgodności traci swą ważność, jeżeli w piecu kominkowym DEFRO HOME SLIMPELL wprowadzono zmiany, został przebudo‐ wany bez naszej zgody lub jest użytkowana niezgodnie z instrukcją obsługi. Niniejsza deklaracja musi być przekazana wraz z piecem ko‐ minkowym w przypadku odstąpienia własności innej osobie. This Declaration of Conformity becomes invalid if any changes have been made to the DEFRO HOME SLIMPELL Dry Stove, if its construction has been changed without our permission or if the dry stove is used not in accordance with the operating manual. This Declaration shall be handed over to a new owner along with the title of ownership of the dry stove. ...
Page 3
Dear Customer, Dear Customer, We would like to thank you for choosing the high quality DEFRO prod- We would like to inform you that we make every efforts to offer uct which will ensure your safety and operational reliability. products of quality fulfilling the most restrictive standards and warrant- As our customers, you can always count on help of the DEFRO Ser- ing operational safety.
Picture 2. Dimensions of dry stove DEFRO HOME SLIMPELL..........................8 Picture 3. Minimum safe distances during setting of dry stove DEFRO HOME SLIMPELL..................9 Picture 4. Connection of the dry stove DEFRO HOME SLIMPELL to external air intake..................10 ...
2. BASIC SAFETY RULES 1. INFORMATION 2.1. SAFETY WARNINGS Operating manual is an integral and essential part of the product The national and local provisions should be met. and must be forwarded to the user also in the case when the property ...
Request a new copy from authorized sales outlet in DE- FRO company if it has been lost. 3. INTENDED USE SLIMPELL dry stoves are intended for combustion of the pellet. They are intended for heating of houses and spaces where they are...
The ceramic lining of the furnace chamber 4.4. FUEL PARAMETRS Sawdust granulate, called pellet, is a primary fuel for the dry stove SLIMPELL. It is recommended to use C1 class pellet in accordance with PN-EN 303-5:2012, with the following parameters: ...
In the case of the floor made of inflammable materials it DEFRO Sp. z o.o. Sp. k. fax 41 303 91 31 is appropriate to prepare a plane protecting the floor Service Centre Ruda Strawczyńska 103a and execute protection in accordance with the stand- serwis@defro.pl 26-067 Strawczyn ards applicable in the given country.
Picture 4. Connection of the dry stove SLIMPELL to external air intake. The external wall near the stove should have through the opening with free cross-section 100 cm (opening with 12 cm in diameter or square 10 x 10 cm), protected with grille on the internal and external side, for this purpose.
Select proper type of the stove on the controller. Start-up with empty feeder (first start-up or start-up when whole Electrical installation of the SLIMPELL dry stove and controller is fuel from the container has been used up): intended for supply from mains with 230 V/50 Hz. Room, where the Select MENU and then select IGNITION.
the stove. Apply a damping (chapter 6.2.2) is necessary (lack of suita- ble draught). 7.1.2. EVERY DAY SERVICE 7. CLEANING AND MAINTENANCE Burner inspection - check whether the openings in burner bottom have proper flow capacity. If they are blocked then you should remove the burner from the recess and clean the All operations related to cleaning of all components openings using a poker, then remove ash using a vacuum...
Clean the recess below the burner with ash. Inspection of fuel level - check whether pellet level in the con- tainer is not lowered then minimum level 25% of container capacity and refill if it is lower. Close the container flap tightly when after fuel refiling.
Remove the left lining made of vermiculite. Remove right strip and remove right lining made of vermiculite. Take out only the upper part of lining. 7.1.6. WINDOW PANEL CLEANING It is recommended use a dry brush to clean the ceramic glass. If the contamination is significant use suitable cleaning agent spray and spray little amount and then clean the window panel with a cloth.
7.3. DISMANTLING OF COMPONENTS 7.3.1. DOORS DISASSEMBLY Open the doors and lift them fully upwards position to remove Remove the upper and bottom side strip and remove the window bottom pin of the hinge from a sleeve. panel. 7.4. SHUTTING THE STOVE DOWN It is recommended completely shut down the stove and clean the equipment when each heating season is finished.
Soot ignition in the chimney is burning of particles deposited inside It is forbidden to damp a fire in a furnace with water. chimney (flue) channels; the deposits are formed in the course of heat- It is forbidden to use a furnace with cracked window panel. ing equipment operation and were not cleaned by chimney sweeps.
30 days after the fault report, if the repair requires replace- damages concerns wearing parts, especially: screws, nuts, ment of constructions elements of the product; handles, ceramic and sealing elements, subject to point 3 and 4 of this warranty conditions. damages resulting from product usage inconsistently with 10) If, as a result of considering the warranty claim the defective prod- the operating manual, that is especially when incorrect...
Page 18
The DEFRO Sp. z o.o. Sp. k. "48h service" does its best to re- move any faults which make it impossible/difficult for the equip- ment to operate within the period of two business days from the day of fault registration. Fault removal time may be prolonged for reasons not dependent on DEFRO Sp.
13. WARRANTY CARD WARRANTY CARD Confirmation of equipment's quality and completeness In accordance with the conditions stated herein, warranty for a dry stove SLIMPELL has been issued type ..........operated in accordance with the operating manual. Equipment manufacturing number* ......................
14. CARRIED OUT WARRANTY REPAIRS AND MAINTENANCE. fault description, repaired element, Stamp and signature date comments description of repairs of Service...
15. WARRANTY CARD /COPY TO SEND BACK/ WARRANTY CARD Confirmation of equipment's quality and completeness In accordance with the conditions stated herein, warranty for a dry stove SLIMPELL has been issued type ..........operated in accordance with the operating manual. Equipment manufacturing number* ......................
16. COMPLAINT FORM COMPLAINT FORM made on ............in connection with complaint no......SUBJECT OF COMPLAINT EQUIPMENT TYPE: ........... Equipment manufacturing date: ..........Equipment serial no.: ........... Equipment purchase date: ..........CLAIMANT Name and surname: ................................Detailed address: ................................................................
17. COMPLAINT FORM COMPLAINT FORM made on............in connection with complaint no... SUBJECT OF COMPLAINT EQUIPMENT TYPE: ........... Equipment manufacturing date: ..........Equipment serial no.: ........... Equipment purchase date: ..........CLAIMANT Name and surname: ................................Detailed address: ................................................................ Phone number ................................
18. COMPLAINT FORM COMPLAINT FORM made on ............in connection with complaint no......SUBJECT OF COMPLAINT EQUIPMENT TYPE: ........... Equipment manufacturing date: ..........Equipment serial no.: ........... Equipment purchase date: ..........CLAIMANT Name and surname: ................................Detailed address: ................................................................
19. REGISTER OF INSPECTIONS OF SMOKE DUCTS date stamp and signature of a chimneysweep date stamp and signature of a chimneysweep...
Page 30
DECLARATION OF PERFORMANCE No. SLIMPELL-01/2018 1. The identification code of product-type KOM-DHSLIMPELL Product name: Dry stove DHSLIMPELL 2. Building product (name, type, series) Serial number: See rating plate. 3. Application of building product Room heater fired with solid fuel in the buildings 4.
Page 31
DEFRO Spółka z ograniczoną odpowiedzialnością Spółka komandytowa plier 00-403 Warszawa Ul. Solec 24/253 Manufacturing plant 26-067 Strawczyn Ruda Strawczyńska 103A MODEL IDENTIFICATION PARAMETERS UNIT OF THE EQUIPMENT SLIMPELL Energy efficiency A⁺ A⁺ class Direct thermal power Indirect thermal power Energy efficiency...
Page 32
service hotline call us: 509 702 720 509 577 900 DEFRO Spółka z ograniczoną odpowiedzialnością Spółka komandytowa 00-403 Warszawa, ul. Solec 24/253 Manufacturing plant: Ruda Strawczyńska 103 A 26-067 Strawczyn tel.: 41 303 80 85, biuro@defro.pl NIP 9591968493...
Need help?
Do you have a question about the SLIMPELL and is the answer not in the manual?
Questions and answers