ENSURE THAT LEADS ARE PROPERLY FUSED AT THE BATTERY. (REFER TO ABYC REC-
OMMENDATIONS.)
Typical d.c. wiring configurations are illustrated in FIGURES 1 and 2.
FIGURE 1: Simple d.c. Wiring (Preferred Method)
Note: These diagrams do not
illustrate complete systems.
Refer to ABYC Standards E-8)
AC Electrical Systems on Boats,
and E-9) DC Electrical Systems
on Boats
*
*Per ABYC A-20: A d.c.
chassis grounding conductor
shall be connected from the
case of the battery charger to
the engine negative terminal or
its bus, and must not be more
than one size under that
required for the d.c. current-
carrying conductors, and not
less than 16 AWG.
IMPORTANT: Install fuses at batteries
per ABYC recommendations.
FIGURE 2: Wiring With Battery Switch
*
*Per ABYC A-20: A d.c.
chassis grounding conductor
shall be connected from the
case of the battery charger to
the engine negative terminal or
its bus, and must not be more
than one size under that
required for the d.c. current-
carrying conductors, and not
less than 16 AWG.
P.O. Box 1306
Newport Beach,
California 92663
www.newmarpower.com
Phone: 714-751-0488
Fax: 714-957-1621
E-Mail: sales@newmarpower.com