tion has caused charger to
have no output
E. High voltage measured
across charger output termi-
nals
F. Charger will not stay in
bulk/absorption phase when
re-initialize button on remote
panel is pressed.
Factory Contact Information
If a problem with your charger persists after you have applied the above-outlined solutions,
or if you have any questions about the installation and proper operation of your charger,
please contact NEWMAR's Technical Services Manager:
Phone: 714-751-0488 — From the hours of 7:00 A.M. to 4:30 P.M. weekdays, P.S.T.
Fax: 714-957-1621 — Anytime
E-Mail: techservice@newmarpower.com — Anytime
We will be happy to consult with you to resolve any problem you may have. If it appears the
charger must be returned to the factory for repair we will issue a Return Materials Authori-
zation at that time.
P.O. Box 1306
Newport Beach,
California 92663
d.c. output fuse and other
internal components likely
blown
1. Batteries not connected
to charger. It is normal to
read 1/2 volt higher across
any output bank when no
batteries are connected.
2. Equalize function is acti-
vated
Batteries at or nearing full
charge (not a problem condi-
tion)
www.newmarpower.com
Replace output fuse with
like type and value. If still
no output, return to servic-
ing dealer for failure analy-
sis or contact NEWMAR for
Return Authorization Num-
ber
1. Check for tight connec-
tion of charging leads to
batteries
2. Check to verify proper
installation and operation of
equalize timer
Verify proper operation by
cycling a.c. off and on (or
press reinitialize button on
optional remote panel) then
applying a large d.c. load