Summary of Contents for ubbink Ubiflux Vigor W400

  • Page 1 INSTALLATION REGULATIONS Ubiflux Vigor W400 English...
  • Page 3 Children may not play with the appliance. If you need a new power cable, always order the replacement from Ubbink NV To prevent dangerous situations, a damaged mains connection must only be replaced by...
  • Page 4: Table Of Contents

    Contents 1 Delivery........5 11.1.4 Connecting extra multiple switch with filter 1.1 Delivery size.
  • Page 5: Delivery

    Before installation of the heat recovery appliance is started, check that it has been supplied in complete and undamaged condition. The delivery size of the heat recovery appliance type Ubiflux Vigor W400 consists of the following components: 1. Heat recovery appliance 2.
  • Page 6: General

    2 General The Ubiflux Vigor W400 and the Ubiflux Vigor W400 Plus is a ventilation unit for the balanced ventilation of dwellings with heat recovery. Features: ▪ Maximum capacity 400 m³/h ▪ High return plastic heat exchanger ▪ Filters ISO Coarse 60% ▪...
  • Page 7: Version

    3 Version 3.1 Technical information Ubiflux Vigor W400 (Plus) Supply voltage [V/Hz] 230V/50Hz 4-0 Version 2-2 Version Dimensions (w x h x d) [mm] 750 x 650 x 560 750 x710 x 560 Duct diameter [mm] ø180 Ext. diameter condensate discharge [mm] ø32...
  • Page 8: Connections And Dimensions

    With a right-hand version the “warm” connections (1 & 3) are on the right-hand side of the appliance. Left-hand version 4-0 connections 2-2 connections Right-hand version 4-0 connections 2-2 connections Ubiflux Vigor W400 615912-D...
  • Page 9 All dimensions in millimeters. Diameter of all collars is 180 mm To dwelling To outside From dwelling From outside Electrical connections Siphon connection Exhaust air filter Supply air filter Mounting Ubiflux Vigor W400 615912-D Ubbink / 9...
  • Page 10: Exploded View Of Appliance

    Power cable 230 volt Preheater Relay output (X19) ) Temperature sensor 24 volt connector (X18) Supply filter eBus connector (X17) Exhaust fan 24 volt connector (X16) Siphon connector Modbus/ bus connector (X15) Supply ventilator Multiple switch connector (X14) Ubiflux Vigor W400 615912-D...
  • Page 11: Operation

    The appliance features a ‘Bypass boost’ function. This means that when this function is switched on (can be switched at step 2.5) the ventilation mode with an opened bypass valve goes to maximum air flow rate (adjustable at step no. 2.6). Ubiflux Vigor W400 615912-D Ubbink / 11...
  • Page 12: Frost Protection

    WiFi signal from the Plus pcb. A standard heat recovery appliance can also later be modified into a Plus version using the Plus pcb upgrade set. 1 = Ubiflux Vigor W400 appliance with mounted Basic pcb 2 = Plus pcb mounting plate...
  • Page 13: Installation

    5.2 Placing the appliance The Ubiflux Vigor W400 (Plus) appliance can be mounted onto the wall with the supplied mounting bracket. For a vibration-free installation, the appliance must be mounted to a solid wall with a minimum mass of 170 kg/m gypsum block or metal stud wall does not suffice! Additional measures such as double panelling or extra studs are required in that case.
  • Page 14: Connecting The Condensate Discharge

    The condensate discharge can be connected, for example, with a straight or angled connection with gasket. Slide the condensate discharge connection with gasket with sufficient length across the connection of the siphon. A = Ubiflux Vigor W400 right- hand version...
  • Page 15: Connecting Air Ducts

    When using flexible mufflers, account must be taken during the installation that these may need to be replaced after a period of time. Install sufficient overflow openings, door gap 2 cm. Ubiflux Vigor W400 615912-D Ubbink / 15...
  • Page 16: Electrical Connections

    1 = Ubiflux Vigor W400 right-hand version (place level) 2 = Preferred ventilation air supply 3 = Sewer release 4 = Preferred location of ventilation air discharge; Use insulated ventilation roof sleeve 5 = Thermally insulated piping 6 = Condensate discharge...
  • Page 17: Connecting The Ebus Connector

    Note: When ModBus is active, the ventilation mode cannot be changed using the display or, if applicable, the connected multiple switch! Also any connected humidity sensor will not function. Ubiflux Vigor W400 615912-D Ubbink / 17...
  • Page 18: Coupling Appliances Using External Bus

    S1 / S2 = Slave appliances (For example a Ubiflux Vigor appliance type 4-0); connect max. of 10 appliances via external Bus All Ubiflux Vigor W400 appliances have the same air flow rate as the appliance that is set as "Master".
  • Page 19: Display

    The desired language/ date & time can be modified in the settings menu ;for this, please refer to the settings value table (® Setting values page 51) step number 15.1 to step number 15.10. Ubiflux Vigor W400 615912-D Ubbink / 19...
  • Page 20: Display Layout

    Filter message symbol; this is only shown if the filter has to be cleaned or replaced. See chapter "Filter cleaning" (® Cleaning filter page 29) for more information. This symbol is only shown if a fault has occurred in the appliance; see chapter Faults (® Fault analysis page 26) for more information. Ubiflux Vigor W400 615912-D...
  • Page 21 Appliance is set as Slave appliance; maximum of 9 appliances can be connected to a Master. Control via eBus for example Air Control . Control via ModBus or external Bus. Bypass boost is active. Ubiflux Vigor W400 615912-D Ubbink / 21...
  • Page 22 Zone Symbol on display Description Internet connection/Network connection Signal strength USB connection active. 11:07 Current set time of the device. 02.01.2020 Current date. Ubiflux Vigor W400 615912-D...
  • Page 23: Display Information

    The touchscreen can also be permanently set as multiple switch; to do this step number 15.6 in the settings menu has to be set to “yes”. Warning: Incorrect settings can seriously disrupt the proper functioning of the appliance! Ubiflux Vigor W400 615912-D Ubbink / 23...
  • Page 24: Starting Appliance

    An exception to this is ventilator mode 0. If mode 0 is chosen on the display: control from other switches, sensors, etc. is not possible. Ubiflux Vigor W400 615912-D...
  • Page 25: Other Settings For Installer

    Under appliance settings, the appliance can be returned to factory settings through step number 15.9. Caution!: With a Ubiflux Vigor W400 Plus, after resetting to the factory setting, step number 14.1 must be reset to external Bus in the settings menu!
  • Page 26: Fault

    Then the appliance will reset itself (Auto reset) and the display returns to the display of the operating situation. Contact the installer to remedy this fault. 1. Supply fan defective A locking fault cannot be remedied by taking the voltage from the appliance; first the fault has to be solved. Ubiflux Vigor W400 615912-D...
  • Page 27 1 E130 E1800 Relay output 1 defective; Signal output not Take voltage from appliance general fault available Replace UWA2-B pcb Fault is automatically reset when voltage is again put back on appliance. Ubiflux Vigor W400 615912-D Ubbink / 27...
  • Page 28 Uncouple postheater and check postheater fuse; replace fuse fuse defective; general comfort control if defective fault message responds Has the fault not yet been remedied: differently Replace external postheater Put voltage back on appliance Fault has automatically been reset Ubiflux Vigor W400 615912-D...
  • Page 29: Maintenance

    The timer of the filter message is then reset! Pressing the Home button brings you back to the main screen from any particular menu; pressing the return button takes you back 1 step in the menu. Ubiflux Vigor W400 615912-D Ubbink / 29...
  • Page 30: Maintenance Siphon

    9.2 Maintenance siphon Cleaning the siphon Every year the siphon must be disconnected and cleaned. (For example a Ubiflux Vigor appliance type 4-0) Ubiflux Vigor W400 615912-D...
  • Page 31: Maintenance

    Installer maintenance includes cleaning the heat exchanger, internal preheater and fans. Dependent on the conditions, this must done about once every three years. Remove the power supply by pulling out the plug. Open the filter door. Remove the two filters. Remove the front cover. Ubiflux Vigor W400 615912-D Ubbink / 31...
  • Page 32 Wash the heat exchanger with hot water (max. 45°C) and a regular detergent. Then rinse the exchanger with hot water. Take EPS assembly, with which the fan is inserted into the appliance, out of the appliance. Ubiflux Vigor W400 615912-D...
  • Page 33 Turn the fan a quarter of a revolution in the appliance. Tilt the fan in such a way that this can be taken out of the EPS assembly; disconnect both fan cables from the fan. Now take the fan out of the appliance. Ubiflux Vigor W400 615912-D Ubbink / 33...
  • Page 34 Reset the timer of the filter message by setting the timer back to zero in the settings menu at step number 4.3. After resetting the timer of the filter message the appliance returns to the main menu and the appliance is once again ready for use. Ubiflux Vigor W400 615912-D...
  • Page 35: Electrical Diagram

    10 Electrical diagram Ubiflux Vigor W400 615912-D Ubbink / 35...
  • Page 36 When the appliance detects another fan (for example when a fan is white replaced during service activities), then a “wizard” starts up grey automatically; follow the instructions on the display for the correct yellow connection of the fan cables. green purple Ubiflux Vigor W400 615912-D...
  • Page 37: Electrical Connections Accessories

    It is best to use a 4-way switch with filter indication; always install an RJ12 connector in combination with a 6- core modular cable. When using a 3-way switch without filter indication always install an RJ11 connector in combination with a 4- core modular cable. Ubiflux Vigor W400 615912-D Ubbink / 37...
  • Page 38: Connecting Position Switch With Filter

    Modular cable: Note: For the modular cable that is used, the “tab” of both modular connectors must be mounted facing the mark on the modular cable. Wire colors C1 - C6 may vary dependent on the type of modular cable used. Ubiflux Vigor W400 615912-D...
  • Page 39: Connecting Wireless Remote Control

    = Modular cable: Note: For the modular cable that is used, the “tab” of both modular connectors must be mounted facing the mark on the modular cable. Wire colors C1 - C6 may vary dependent on the type of modular cable used. Ubiflux Vigor W400 615912-D Ubbink / 39...
  • Page 40: Connecting Extra Multiple Switch With Filter

    = Modular cable: Note: For the modular cable that is used, the “tab” of both modular connectors must be mounted facing the mark on the modular cable. Wire colors C1 - C6 may vary dependent on the type of modular cable used. Ubiflux Vigor W400 615912-D...
  • Page 41: Connecting Extra Multiple Switch With Filter

    = Modular cable: Note: For the modular cable that is used, the “tab” of both modular connectors must be mounted facing the mark on the modular cable. Wire colors C1 - C6 may vary dependent on the type of modular cable used. Ubiflux Vigor W400 615912-D Ubbink / 41...
  • Page 42: Connecting Air Control

    11.2 Connecting Air Control A = Ubiflux Vigor appliance B = Air Control (option) C = Two-core control cables D = Green two-pole screw connector E = Position green eBus connector to rear of control Ubiflux Vigor W400 615912-D...
  • Page 43: Connecting Humidity Sensor

    4 = The cable that comes with RH cable 5 = RH (humidity) sensor 6 = Duct from dwelling To switch on and set the sensitivity of the humidity sensor, go to step number 7.1 and 7.2 in the settings menu Ubiflux Vigor W400 615912-D Ubbink / 43...
  • Page 44: Connecting Co₂ Sensor(S)

    6.1 in the settings menu ; in order to set the minimum and maximum PPM value of the CO sensor(s) set, if necessary, the right values following step numbers 6.2 to 6.9. Ubiflux Vigor W400 615912-D...
  • Page 45: Demand-Driven Ventilation 2.0

    5 = EBus connection X17 on Ubiflux Vigor appliance C11 = green 6 = CO -sensors (only applicable when demand-driven based on CO 7 = Pcb demand-driven 8 = Dipswitch setting on pcb zone valve Ubiflux Vigor W400 615912-D Ubbink / 45...
  • Page 46: Connecting Postheater

    2 = Maximum safety with manual reset C3 = green/yellow 3 = 2-pole eBus connection X17 on appliance C4 = black 4 = Temperature sensor C5 = white 5 = PCB type UVP1 6 = Airflow direction 7 = Dipswitch setting postheater Ubiflux Vigor W400 615912-D...
  • Page 47: Connecting Preheater

    C3 = green/yellow 3 = 2-pole eBus connection X17 on appliance C4 = black 4 = Temperature sensor C5 = white 5 = PCB type UVP1 6 = Airflow direction 7 = Dipswitch setting preheater Ubiflux Vigor W400 615912-D Ubbink / 47...
  • Page 48: Connecting Geo-Heat Exchanger

    0.0 °C / 10.0 °C 11.3 Switch temperature 2 25°C 15.0°C / 40.0 °C 11.4 Mode valve 10 volt control Closed Open / Closed Relay output 1/Relay output 2/ 11.5 Valve control Relay output 1 Analogue output 1/Analogue output 2 Ubiflux Vigor W400 615912-D...
  • Page 49: Service

    N.B.: Appliance type, serial number and year of production are stated on the identification plate behind the plastic front panel on the appliance. Example Appliance type Ubiflux Vigor W400 Serial number 431030201201 Year of production 2021 Part Article code 0884055 Quantity Ubiflux Vigor W400 615912-D Ubbink / 49...
  • Page 50 The power cable is fitted with a circuit board connector. When replacing it, always order a replacement mains cable from . To prevent dangerous situations, a damaged mains connection can only be replaced by a qualified expert. Ubiflux Vigor W400 615912-D...
  • Page 51: Setting Values

    13 Setting values 13.1 Setting values standard appliance The below setting values are for a Ubiflux Vigor W400-appliance without Plus pcb. Step Description Factory settings Setting range Comment Flow rate Air flow rate setting 0 50 m³/h 0 or adjustable between 50 m³/h and 400 m³/h (never higher than step no.
  • Page 52 (0=Master; 1 t/m 9 = Slave 1 t/m Slave 9) Central heating + heat recovery 12.1 Status On / Off Communication 14.1 Type of Bus connection ModBus Off / ModBus/ external Bus 14.2 Slave address 1 - 247 For Modbus Ubiflux Vigor W400 615912-D...
  • Page 53 15.10 Fan position wizard Yes / No Signal output 16.1 Signal output Off / Only filter condition / Only fault Connector X19 condition / Filter and fault condition Standby 17.1 Switch off appliance Yes / No Ubiflux Vigor W400 615912-D Ubbink / 53...
  • Page 54: Setting Values Appliance With Plus Pcb

    13.2 Setting values appliance with Plus pcb The below setting values are for a Ubiflux Vigor W400-appliance with Plus pcb. Step Description Factory settings Setting range Comment Switch contacts Make or break contact 1 Make Make / Break Switch contact control 1...
  • Page 55 25 °C 15.0°C / 40.0 °C 11.4 Mode valve 24 volt control Closed Open / Closed 11.5 Valve control Relay output 1 Relay output 1/ Relay output 2/ Analogue output 1/ Analogue output 2 Ubiflux Vigor W400 615912-D Ubbink / 55...
  • Page 56: Conformity Declaration

    Jan Samijnstraat 9 BE-9050, Gentbrugge, Belgium Product: Heat recovery appliance type: Ubiflux Vigor W400 Ubiflux Vigor W400 Plus The product described above complies with the following directives: ¨ 2014/35/EU (low voltage directive) ¨ 2014/30/EU (EMC directive) ¨ RoHS 2011/65/EU (substances directive) ¨...
  • Page 57: Erp Values

    15 ERP values Technical information sheet Ubiflux Vigor W400 (Plus) in accordance with Ecodesign (ErP), no. 1254/2014 (Annex Manufacturer: Ubbink NV Model: Ubiflux Vigor W400 (Plus) Climate Type of control SEC Value in Annual Annual heating zone kWh/m²/a Class saved (AHS) in...
  • Page 58 SEC in kWh/m²/a A+ (Most efficient) SEC < -42 -42 ≤ SEC < -34 -34 ≤ SEC < -26 -26 ≤ SEC < -23 -23 ≤ SEC < -20 G (Least efficient) -20 ≤ SEC < -10 Ubiflux Vigor W400 615912-D...
  • Page 59: Recycling

    16 Recycling Recycling Sustainable materials are used in the manufacture of this appliance. The packaging should be disposed of in a responsible manner and in accordance with governmental regulations. Ubiflux Vigor W400 615912-D Ubbink / 59...